background image

Ethernet™ 2-Port

Multi Media Repeater

20

CAUTION:  RJ connectors are NOT INTENDED FOR
CONNECTION TO THE PUBLIC TELEPHONE
NETWORK. Failure to observe this caution could result
in damage to the public telephone network.

Compliance Information
UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class
A digital device, pursuant to part 15 of the FCC rules.  These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.  This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for
digital apparatus set out on the radio interference regulations of the Canadian
Department of Communications.

European Regulations
Warning

This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.

Copyright Restrictions

©  1995, 1996 TRANSITION Networks Inc.
All rights reserved.  No part of this work may be reproduced or used in any
form or by any means – graphic, electronic, or mechanical – without written
permission from TRANSITION Networks Inc.

Trademark Notice

All registered trademarks and trademarks are the property of their respective
owners.

Der Anschluss dieses Gerätes an ein öffentlickes
Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die
jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie
91/263/EWG zur Angleichung der Rechtsvorschriften der
Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

10Base2 Cable Specifications

The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802.3
10Base2 specifications. 

Cable Characteristics: 

Cable type:

Stranded Coaxial RG58 (ThinNet)

Impedance: 50 

@ 10 MHz 

Mutual Capacitance:

24 pF/ft ±20% @ 10 MHz

Maximum Cable Length

:

185 meters (610 feet)

Maximum number network connections:

30

Minimum distance between connections:

0.5 meters (1.6 feet)

Terminate 10Base2 cable at one end using a 50 ohm terminator and at the

other end using a 50 ohm terminator grounded to earth ground.

10BaseT Cable and Connector Specifications

The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802.3
10BaseT specifications. 

10BaseT Cable Characteristics: 

Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

Gauge

24 to 22 AWG

Attenuation 

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Category 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Maximum Cable Length:

100 meters (330 feet)

10BaseT Connector Characteristics:

The two active pairs  in a 10BaseT network are pins 1 & 2 and pins 3 & 6. Use
only dedicated wire pairs (such as blue/white & white/blue, orange/white &
white/orange) for the active pins. 10BaseT cable for unlike devices (such as
hub to terminal device) must be configured as straight through; 10BaseT cable
for like devices (such as hub to hub or terminal device to terminal device) must
be configured as crossover.

Twisted
Pair  #1

Twisted
Pair  #2

Crossover Cable

Connectors for like devices

1

2

3

6

1

2

3

6

1

2

3

6

Twisted
Pair  #1

Twisted
Pair  #2

Straight Through Cable

Connectors for unlike devices

1

2

3

6

Summary of Contents for E-MMR-2

Page 1: ...02 3 Physical Dimensions 7 1 x 5 1 x 2 5 180 mm x 130 mm x 64 mm Input Power Power Supply Adapter AC Input TN PN Requirement Location 3518 120 volts 60 hertz 28 watts USA Canada Mexico 3516 230 volts 50 hertz 28 watts Europe 3514 100 volts 50 60 hertz 28 watts Japan 3517 240 volts 50 hertz 28 watts United Kingdom 3515 240 volts 50 hertz 28 watts Australia DC Output 9 volts at 500 mA maximum MTBF 4...

Page 2: ... die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802 3 10Base2 specifications Cable Characteristics C...

Page 3: ...king posts AUI Connection Cable shell must be grounded Connector Legend 1 Logic Ref 6 Power Return 11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Ca...

Page 4: ...hether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial...

Page 5: ...r 612 941 7600 Fax 612 941 2322 E mail techsupport transition com Internet http www transition com THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A...

Page 6: ...observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two network devices fail to communicate through the 0403 Pocket consider the following Are the LEDs described in the previous section functioning properly Do network devices have Link Integrity enabled Do network devices...

Page 7: ...received 2 SITE CONSIDERATIONS The site for the Multi Media Repeater must provide AC power outlet for each Multi Media Repeater Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same co...

Page 8: ...tween cable interfaces in an Ethernet LAN NOTE Up to one hundred 10Base5 connections can be made in one segment To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the terminals segment 1 and the segment connected to ...

Page 9: ...ive RX ST connectors to fiber optic cable Ensuring Correct 10BaseT Configuration The 10BaseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections must be configured as crossover The two active pairs in a 10BaseT network are pins 1 2 and pins 3 6 Use only dedicated wire pairs such as blue white whit...

Page 10: ...IC Redundant Fiber Optic E FL RED SIC Female AUI Connector 10Base5 Transceiver Connection The female AUI card E AUI DT SIC provides a female AUI connector for connection to 10Base5 through an AUI drop cable or to 10Base2 10BaseT or10BaseFL through a transceiver NOTE The bridge card E BR SIC also provides a female AUI connector Connecting 10Base5 Using AUI Drop Cable To connect 10Base5 Cable to 8 P...

Page 11: ...ale RJ 45 plug connector at other end of 10BaseT cable to DTE terminal RJ 45 jack connector using crossover cable orientation or to RJ 45 jack connector using straight through cable orientation Ethernet 2 Port Multi Media Repeater 8 11 Installing Multi Media Repeater on Flat Surface To install the Multi Media Repeater on table shelf or other flat surface 1 Carefully turn Multi Media Repeater to si...

Page 12: ... Card components facing up carefully guide the Slide In Card along the card guides until the Slide In Card connector meets the the Multi Media Repeater backplane 3 Firmly push the card into the slot until the Slide In Card faceplate is flat against the Multi Media Repeater frame 4 Rotate the Slide In Card thumbscrews into the Multi Media Repeater threaded holes SQE Switch Connecting Cable to SIC a...

Reviews: