Dimensions 

Figure 3 shows the E-TBT-MC05 dimensions. 

 

Figure 3: E-TBT-MC05 Dimensions 

Features 

 

Provides a complete interface of the AUI to Ethernet UTP cable. 

 

Supports 10Mbps data transfer rates. 

 

Supports Carrier Sense Multiple Access/Collision Detection (CSMA/CD) contention protocol. 

 

Drives UTP cable segments up to 100 meters (328ft). 

 

Supports selectable link and SQE test functions. 

 

Supports direct connections to host AUI ports. 

 

Detects and corrects reverse polarity on the receiving pair of UTP cables. 

 

Provides four LEDs: Transmit (TX), Receive (RX), Collision, and Status. 

 

 

Summary of Contents for E-TBT-MC05

Page 1: ...rations 2 Front and Back Panels 2 Dimensions 3 Features 3 Connectors and Cables 4 AUI Male Connector 4 UTP Cable RJ 45 Connector 5 Wiring schemes for UTP cable and devices 6 Installation 7 Switches 7...

Page 2: ...ctly or through an AUI cable to an Ethernet 10BASE T device The Ethernet device is connected to the transceiver through an unshielded or shielded twisted pair copper cable with RJ 45 connector ends Va...

Page 3: ...of the AUI to Ethernet UTP cable Supports 10Mbps data transfer rates Supports Carrier Sense Multiple Access Collision Detection CSMA CD contention protocol Drives UTP cable segments up to 100 meters 3...

Page 4: ...hub via an AUI drop cable The AUI connector is shown in Figure 4 The AUI male connector pin assignments are show in Table 1 Figure 4 E TBT MC05 AUI Male Connector Pin Assignments Table 1 AUI Male Conn...

Page 5: ...P cable Use category 3 4 or 5 UTP cable The length of the UTP cable can be up to 100m 328ft The RJ 45 connector pin configuration is shown in Figure 5 The pin assignments are show in the Table 2 Figur...

Page 6: ...UTP cable is determined by the characteristics of the 10Base T UTP port of the other device The following shows some pinning examples Note The device 10Base T output jack is normally used to connect...

Page 7: ...isable the SQE test function or to the UP position to enable the test The SQE Test heartbeat is a means of detecting a transceiver s inability to detect collisions Without this test it would not be po...

Page 8: ...MPORTANT If the transceiver is attached to an Ethernet repeater a10Base T hub or a wiring concentrator the SQE test function should be disabled To connect the transceiver to a 10Base T device via RJ 4...

Page 9: ...al status of the transceiver The following table explains LED indications LED Description Collision Blinks when detects a collision Status ON Solid UTP link established Blinks No UTP link 5 Blink patt...

Page 10: ...g Twisted Pair TP Ethernet USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are intended connecting to intrabuilding inside plant link segments not subject to lightening transients or power faults Copper...

Page 11: ...the AUI device is turned ON Verify that the AUI cable from the transceiver to the AUI device port is installed properly Contact Tech Support see Contact Us below YES Go to step 2 2 Is the RX LED flash...

Page 12: ...952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 sales transition com techsupport transition com customerservice transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 5...