background image

IONPS-A, AC Power Module

2

Tech Support:  1-800-260-1312 – International:  00-1-952-941-7600 – (24 hours)

Table of contents

Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Definitions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cautions and warnings in this manual  . . . . . . . . . . . . . . . . . . . . . . . . .3

Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Power Module component identification . . . . . . . . . . . . . . . . . . . . . . .4
Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Power Module redundancy  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installing an optional Power Module into the ION chassis  . . . . . . . . .6
Connecting external power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Replacing the Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Replacing the fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Technical Specification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Contact Us  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Compliance Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

techsupport@transition.com – Click the “Transition Now” link for a live Web chat.

3

Cautions and Warnings

Definitions

Cautions indicate potential damage to equipment.

Warnings indicate a potential hazard or injury to people.

Cautions and warnings in this manual

Cautions and warnings are explained here and placed throughout this manual where
appropriate. 

CAUTION: While installing or servicing the Power Module, wear a grounding
device and observe all electrostatic discharge precautions. Failure to observe this
caution could result in damage or failure of the Power Module.

WARNING: Do not connect the Power Module to an external power source before
installing it into the chassis. Failure to observe this warning could result in an
electrical shock, even death. 

WARNING: A readily accessible, suitable National Electrical Code (NEC) or
local electrical code approved disconnect device and branch-circuit protector must
be part of the building's installed wiring to accommodate permanently connected
equipment. Failure to observe this warning could result in an electric shock, even 
death.

WARNING: Turn the Power Module and external power source OFF and ensure
that the Power Module is disconnected from the external power source before
performing any maintenance. Failure to observe this warning could result in an
electrical shock, even death.

Summary of Contents for IONPS-A

Page 1: ...IONPS A AC Power Module User Manual 33423 A ...

Page 2: ...re and placed throughout this manual where appropriate CAUTION While installing or servicing the Power Module wear a grounding device and observe all electrostatic discharge precautions Failure to observe this caution could result in damage or failure of the Power Module WARNING Do not connect the Power Module to an external power source before installing it into the chassis Failure to observe thi...

Page 3: ...ION While installing or servicing the Power Module wear a grounding device and observe all electrostatic discharge precautions Failure to observe this caution could result in damage or failure of the Power Module Description continued Notices The IONPS A AC Power Module must be installed by qualified technical personnel only Transition networks assumes no responsibility for the improper installati...

Page 4: ... do the following Note The procedure is the same for installing the Power Module into either slot 1 Push the Power Module ON OFF switch to the OFF position See Figure 2 Power Module Switch OFF Position Figure 2 Power ON OFF Switch Installation Continued techsupport transition com Click the Transition Now link for a live Web chat 7 3 Remove the slot cover from the right chassis slot and keep the tw...

Page 5: ...2 Make sure that the Power Module ON OFF switch is in the OFF position See Figure 7 3 Plug the female end of the AC power cord into the AC power receptacle on the Power Module See Figure 7 4 Plug the male end of the AC power cord into the AC power source 5 Turn the power ON OFF switch to the ON position See Figure 7 Note Once the power ON OFF switch is in the ON position the power ON LED will lite...

Page 6: ...e Mounting Screws Power Module Chassis 4 Remove the two screws securing the Power Module to the chassis 5 Carefully pull the Power Module from the chassis See Figure 9 techsupport transition com Click the Transition Now link for a live Web chat 11 Figure 10 Power ON OFF Switch Maintenance Continued Installing the Power Module continued 6 Locate the new Power Module 7 Push the power ON OFF switch t...

Page 7: ...he same amperage and voltage rating 6 Insert the fuse into the holder 7 Slide the fuse holder fully into the Power Module 8 Connect the power cord to Power Module and to the external power 9 Push the power ON OFF switch to the ON position Figures 11 A B Replacing Fuse techsupport transition com Click the Transition Now link for a live Web chat 13 Technical Specification For use with Transition Net...

Page 8: ...national 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff t...

Page 9: ...ial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Cana...

Reviews: