background image

2

J/E-CX-TBT-02 

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  

Power the media converter

NOTE: 

The external power supply provided with this product is UL listed by the

manufacturer.

Before you begin: Only qualified technical personnel should install this media
converter.

1. Connect the barrel connector on the power adapter to the media converter’s

power port 

(located on the back of the media converter)

2. Plug the AC end of the power adapter into an appropriate AC power outlet.

3. Verify that the LED power indicator light is ON; if it is not, see the

Troubleshooting section in this manual. 

Installation

Checklist

The box should contain the following:

• Converter

• AC/DC power converter

• T-Connector 

(for TP-BNC converter)

Contact your sales representative if any item is missing. 

TP-BNC Converter LED Functions

LED description

Use the LEDs to monitor media converter operation in the network. 

LED

Color

Function

BNC/Act

Green

Flashing = 10base-2 data traffic

TP/Act

Green

• ON = 10Base-T link connection
• Flashing = 10Base-T data traffic

Col

(Collision)

Amber

Flashing = collision present

Pwr 

(Power)

Green

ON = connected to external power

Pwr

Cal

TP

BNC

ACT

BNC Port

RJ-45 Port

3

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

Installation -- continued

Install the coax cable

1. Locate or build 10Base-2 compliant coax cable with female, BNC

connectors installed at both ends.

2. Connect the BNC cable connector at one end of the cable to the BNC port

on the media converter.

3. Connect the BNC cable connector at the other end of the cable to the BNC

port on the 10Base-2 compliant device.

CAUTION: Ensure that the 10Base-2 coax cables are terminated properly at
both ends. In a coax thinnet installation, terminate the first and last device in the
daisy-chain with a 50 

terminator. Also, ensure that the 10Base-2 segment is

grounded to earth ground at a single point.  Failure to observe this caution will
cause data transfer failures.

Connect the coax cable 
to the first media 
converter as shown.

Connect the coax cable

to the 10Base-2 compliant

device as shown

RJ-45 port

on the other device

(switch, work station, etc.)

RJ-45 port

on the media 

converter

Install the 10Base-T cable 

CAUTION: Set the MDI/MDI-X switch 

(located on the side of the converter) 

to

MDI-X 

(default) 

when connecting the J/E-CX-TBT-02 to a hub, switch, or router.

Set the switch to MDI when connecting to a terminal, transceiver, or NIC. Failure
to observe this caution will cause loss of data.

1. Locate or build 10Base-T compliant copper cables with male, RJ-45

connectors installed at both ends.

2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the

media converter, as shown below.

3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on

the 10Base-T compliant device, as shown below.

MDI/MDI-X

MDI/MDI-X Switch

Summary of Contents for J/E-CX-TBT-02

Page 1: ...ned devices on one coax segment per twisted pair segment User s Guide J E CX TBT 02 Stand Alone Media Converter Coax to twisted pair 10Base 2 to 10Base T Installation 2 Cable Specifications 4 Technical Specifications 5 Troubleshooting 6 Contact Us 7 Typical maximum cable distance The actual maximum cable distances are dependent upon the physical characteristics of the network installation J E CX T...

Page 2: ...ild 10Base 2 compliant coax cable with female BNC connectors installed at both ends 2 Connect the BNC cable connector at one end of the cable to the BNC port on the media converter 3 Connect the BNC cable connector at the other end of the cable to the BNC port on the 10Base 2 compliant device CAUTION Ensure that the 10Base 2 coax cables are terminated properly at both ends In a coax thinnet instal...

Page 3: ...rk RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD Use only dedicated wire pairs for the active pins e g blue white and white blue orange white and white orange etc Do not use flat or silver satin wire Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3 6 5 techsupport transition com Click the Transition Now link for a ...

Page 4: ...initialization process Contact Technical Support YES Contact Technical Support 6 J E CX TBT 02 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 7 techsupport transition com Click the Transition Now link for a live Web chat Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model J E CX TBT 02 Series Media Converters P...

Page 5: ...partment of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European regulations Warning This is a Class A product In a domestic environment this product may cause radio interf...

Reviews: