background image

Transition

 

Networks

 

 

N

GXE

xx

02

 

User

 

Guide

 

33748

 

Rev.

 

A

 

https://www.transition.com/

 

Page

 

16

 

of

 

26

 

Teaming  

The

 

Teaming

 

tab

 

lets

 

you

 

specify

 

whether

 

a

 

network

 

connection

 

will

 

participate

 

in

 

a

 

team.

 

If

 

not

 

checked

 

this

 

adapter

 

is

 

not

 

part

 

of

 

a

 

team.

 

Advanced

 

Networking

 

Services

 

(ANS)

 

teaming

 

is

 

a

 

feature

 

of

 

the

 

Intel®

 

Advanced

 

Networking

 

Services

 

component

 

that

 

lets

 

you

 

group

 

multiple

 

adapters

 

in

 

a

 

system

 

into

 

a

 

team.

 

ANS

 

teams

 

offer

 

features

 

such

 

as

 

load

 

balancing,

 

increased

 

throughput,

 

and

 

fault

 

tolerance.

  

The

 

network

 

configuration

 

as

 

well

 

as

 

the

 

type

 

of

 

adapters

 

installed

 

in

 

your

 

computer

 

affect

 

which

 

team

 

types

 

can

 

be

 

set

 

up

 

on

 

the

 

computer.

  

Cable Specifications 

Fiber

 

cable

 

Multimode

 

fiber

 

(recommended):

  

62.5/125

 μ

m

 

Multimode

 

fiber

 

(optional):

  

 

50/125

 μ

m

 

N

GXE

SC

02

    

 

 

850

 

nm

 

multimode

 

Fiber

 

optic

 

transmitter

 

power:

    

min:

 ‐

9.5

 

dBm

  

max:

 ‐

4.0

 

dBm

 

Fiber

 

optic

 

receiver

 

sensitivity:

    

min:

 ‐

17.0

 

dBm

  

max:

 ‐

17.0

 

dBm

 

Link

 

budget:

  

 

 

 

8.0

 

dB

 

N

GXE

LC

02

    

 

 

850

 

nm

 

multimode

 

Fiber

 

optic

 

transmitter

 

power:

    

min:

 ‐

9.5

 

dBm

  

max:

 ‐

4.0

 

dBm

 

Fiber

 

optic

 

receiver

 

sensitivity:

    

min:

 ‐

17.0

 

dBm

  

max:

 

3.0

 

dBm

 

Link

 

budget:

  

 

 

 

8.0

 

dB

 

N

GXE

ST

02

    

 

 

850

 

nm

 

multimode

 

Fiber

 

optic

 

transmitter

 

power:

    

min:

 ‐

9.5

 

dBm

  

max:

 ‐

4.0

 

dBm

 

Fiber

 

optic

 

receiver

 

sensitivity:

    

min:

 ‐

17.0

 

dBm

  

max:

 ‐

17.0

 

dBm

 

Link

 

budget:

  

 

 

 

8.0

 

dB

 

N

GXE

SFP

02

   

 

 

Supports

 

both

 

Single

 

mode

 

and

 

Multi

mode

 

SFP

 

modules

 

The

 

fiber

 

optic

 

transmitters

 

on

 

the

 

device

 

meet

 

Class

 

I

 

Laser

 

safety

 

requirements

 

per

 

IEC

825/CDRH

 

standard

 

and

 

comply

 

with

 

21CRF1040.10

 

and

 

21CRF1040.11.

 

Network Parameters 

Multimode

 

Fiber

 

Cable

 

and

 

Modal

 

Bandwidth

 

Per

 

IEEE

 

802.3z

 

Gigabit

 

Ethernet

 

1000SX

 

850nm

 

Multimode:

 

62.5/125um

 

Modal

 

Bandwidth

 

160Mhz

km:

 

Distance:

 

220m

 

Modal

 

Bandwidth

 

200Mhz

km:

 

Distance:

 

275m

 

Multimode:

 

50/125um

 

Modal

 

Bandwidth

 

400Mhz

km:

 

Distance:

 

500m

 

Modal

 

Bandwidth

 

500Mhz

km:

 

Distance:

 

550m

 

 

 

Summary of Contents for N-GXE Series

Page 1: ...ailover support Supports IPv4 and IPv6 Supports TCP segmentation offload up to 256 Kb Contents Contents 1 Introduction 2 Ordering Information 2 Application Example 3 Installation 3 Package Contents 3...

Page 2: ...nd Wake on LAN the adapter provides enhanced performance flexible configuration and secure networking for users in a standard based environment An LED indicator on the bracket displays link status act...

Page 3: ...ystem Requirements PCI Express enabled computer system with available PCI Express slot Supported OS ACPI aware OS for support of remote wake up WOL The latest BIOS on your computer One open PCI Expres...

Page 4: ...ets 1 Ground yourself to dissipate any static charge 2 Remove the two screws securing the standard bracket to the back side of the NIC 3 Slide the standard bracket away from the NIC 4 Slide the low pr...

Page 5: ...g and disconnect the PC and then wait for 15 20 seconds before plugging the NIC into the PC When removing the NIC unplug the Ethernet cable before removing the PC cover To install the N GXE NIC do the...

Page 6: ...sconnect all cables before removing or installing an SFP module 3 Insert the SFP fully into the cage 4 Position the LC fiber cable at the SFP 5 Insert the LC fiber cable end completely into the SFP 6...

Page 7: ...Device Manager from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as I210 Gigabit Fiber Connection 4 Optional at this point you can set up advanced fea...

Page 8: ...default when you install the device drivers Intel PROSet for Windows Device Manager is installed with the same process used to install drivers You must have administrator rights to install or use Inte...

Page 9: ...download directory 3 Click Install Drivers and Software and follow the instructions in the install wizard Intel R PROSet functionality is integrated with the Windows Device Manager To configure Intel...

Page 10: ...ip the driver to your computer e g for Windows 7 64 bit OS the driver should be unzipped in the C WINDOWS7 64 directory 3 Shut down the computer and then remove the N GXE NIC from the computer 4 Run W...

Page 11: ...er from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as Intel I210 Gigabit Fiber Network Connection 4 Navigate to the required tab e g the Driver tab 5...

Page 12: ...gement APM Support o Advanced Configuration and Power Interface ACPI Specification v2 0c o Magic Packet Wake up enable Jumbo frames support up to 9014 bytes IPv4 and IPv6 o IPv4 checksum offloading TC...

Page 13: ...tware solution allowing a computer to be woken up remotely Being able to power up a remote computer lets an administrator perform off hours maintenance at a remote site without having to send a techni...

Page 14: ...s calculated by the NIC instead of the system CPU This reduces CPU load and can improve system performance in high traffic environments There is typically no need to disable checksum offload Fragmente...

Page 15: ...the VLAN may have a momentary loss of connectivity A VLAN cannot be removed if a virtual NIC is bound to it The VLANs tab includes Name column Displays the name assigned to the VLAN ID Column Displays...

Page 16: ...r optic transmitter power min 9 5 dBm max 4 0 dBm Fiber optic receiver sensitivity min 17 0 dBm max 17 0 dBm Link budget 8 0 dB N GXE LC 02 850 nm multimode Fiber optic transmitter power min 9 5 dBm m...

Page 17: ...XE xx 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE xx 02 40C 658 260 Bellcore7 V5 0 Hours MTBF SFP N GXE SFP 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE SFP 02 40C 658 260 Bellcore7 V5 0 Hours Warranty L...

Page 18: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 18 of 26 Dimensions Standard Bracket...

Page 19: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 19 of 26 LP Bracket...

Page 20: ...OK Off link fail Flash link OK activity Green Full duplex Yellow Half duplex L A Link Activity SFP Version On Communication link Off Link Fail Flash Link OK and Activity Green 1 Gbps Yellow 100 Mbps I...

Page 21: ...hat is slowing down your system Processor and memory Check your performance monitoring programs and see if traffic is being affected by your processor speed available memory or other processes Transmi...

Page 22: ...her slot 8 Use the troubleshooting procedures in the computer s user guide 9 Use the troubleshooting procedures on the PXE Boot Loader webpage as required 10 Use the troubleshooting procedures on the...

Page 23: ...______________ PC s Icon Tray indication ________________________________________________________________ Connected Device s ___________________________________________________________________ Cable t...

Page 24: ...Device Label Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526...

Page 25: ...des Communications du Canada European Regulations Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse B In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F...

Page 26: ...91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Record of Revisions Rev Dat...

Reviews: