Grounding the Media Converter
The dual-slot chassis comes equipped with grounding lugs located on the back panel.
They require a grounding conductor wire terminated with a two-hole, compression-
type, grounding connector. The grounding wire -- which must be a copper conductor -
- is not included with the chassis and must be provided by the customer/installer.
The electrical conducting path from the dual-slot chassis must:
•
Flow via the grounding lugs to the common bonding network (CBN) for telecom
installations, or to an alternative approved grounding system
(if required)
for non-
telecom installations.
•
Be of sufficiently low impedance to conduct fault currents likely to be imposed on
the media converter, and
•
Enable proper operation of any over-current protection devices.
The conductor must be fastened to the grounding lugs with the enclosed anti-rotation
star-washers and lug-nut fasteners. The applied torque required to the connector lug-
nut fasteners is specified by the connector’s manufacturer.
To properly ground the dual-slot chassis:
1.
Obtain one (1) grounding conductor
(12 AWG copper wire gauge or larger)
with a
two-hole, compression-type, grounding connector.
2.
Attach the grounding conductor to the converter by placing the two-hole
connector onto the grounding lugs and fasten with the enclosed lock-washers /
lug-nuts at the proper torque
(per the manufacturer’s specification).
3.
Attach the opposite end of the
grounding conductor to the
common bonding network
(CBN) for telecom, or to earth
ground
(if required)
for non-
telecom installations.
Grounding Lugs
Connect to E arth Ground
¾"
Grounding S crew
6-32 x 1/8"
St ar Was her
Lug Nut
12 AWG Copper Wire
(not included)
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Technical Specifications
For use with Transition Networks Model CPSMC0200-22x or equivalent.
Note:
The CPSMC0200-22x dual-slot chassis is Class B compliant ONLY if Class
B-compliant media converters are installed. Installation of a Class A-
compliant media converter reduces the chassis to Class A compliance.
The maximum power delivery capacity for each chassis slot is 12 Watts with an
aggregate chassis maximum of 6 watts per slot. Example: A 12-Watt media converter
would require the power of both slots. In this example, the second slot must remain
unused.
Compliance
EN55022; Class A&B; CE Mark
Dimensions
5.7 x 5.5 x 2.2 in
(145 x 139.7 x 56 mm)
Weight 1.8
lb.
(0.817kg.)
approximately
*MTBF:
48,501 hours
(MIL217F2 V5.0) (MIL-HDBK-217F)
128,553 hours
(Bellcore7 V5.0)
Maximum power delivery capacity:
CPSMC0200-22x:
12 Watts
Power Supplies
Shipped: 12VDC, 1.25A, 100-240VAC, 50/60Hz
Optional: 12VDC, 2.5A, 100-240VAC, 50/60Hz
Environment
Tmra**:
0
°
to 60°C
(32 to 140° F )
Storage Temp:
-20
°
to 85°C
Humidity:
10 to 90%, non-condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
The information in this user’s guide is subject to change. For the most up-to-date
information on the CPSMC0100-22x dual-slot chassis, view the user’s guide on-line
at: www.transition.com.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view the beam directly with optical instruments. Failure to observe this
warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
*MTBF is estimated using the predictability method. This method is based on MIL-
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C, and nominal
operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature for the dual-slot chassis. Refer to the
user’s guide of the installed media converter for its operating temperature range.