11
CPSMC13xx-100 PointSystem
™
Chassis
slide-in-modules
2.2.3
Replacing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when replacing the management module(s). Failure to observe this
caution could result in damage to, and subsequent failure of, the management
module(s).
NOTE:
The management modules can be replaced while the chassis remains
powered. However,
you must configure a new IP address for the replacement
management module
. For more information, see the
FocalPoint™ 2.0
user’s guide
on the enclosed application CD or on-line at www.transition.com.
To replace a management module in the CPSMC13xx-100 chassis:
1. Remove the management module to be replaced by loosening the panel
fastener screw that secures the module to the chassis front. Slide the module
from the chassis.
2. Align the replacement module with the installation slot so that the panel
fastener screw is at the top.
3. Carefully slide the replacement management module into the installation slot,
while aligning the module’s circuit board with the installation guides.
NOTE:
Ensure that the management module is firmly seated inside the chassis.
4. Rotate the attached panel fastener screw clockwise to secure the module to the
chassis.