Transition Networks
SMxxTAT4Xx Install Guide
33785 Rev. B
Page
14
of
43
Power Consumption
SM48TAT4XA-RP Power Consumption
2-module Power
AC 100V Input
DUT Status
DUT Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
100
16.74
0.97
1674.00
1623.78
Non-PoE
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
100
1.01
0.95
101.00
95.95
AC 110V Input
DUT Status
DUT Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
110
15.09
0.98
1659.90
1626.70
Non-PoE
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
110
0.93
0.94
102.30
96.16
AC 220V Input
DUT Status
DUT Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
220
7.34
0.97
1614.80
1566.36
Non-PoE
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
220
0.60
0.70
132.00
92.40
AC 240V Input
DUT Status
DUT Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
240
6.69
0.97
1605.60
1557.43
Non-PoE
Full-loading
60 minutes later
1G TP Port x 48
10G SFP x 4
240
0.61
0.65
146.40
95.16