24-Hour Technical Support: 

800-260-1312

-- International: 

952-941-7600

SPS-1872-xx

Installation and Service

All Installation and service must be performed by qualified service personnel.

Read and follow all warning notices and instructions marked on the product or
included in the manual.

Required Grounding

This product is intended to be used in a restricted access location  Connect the
device to a 48 VDC SELV 

(Safety Extra Low Voltage) 

supply that is electrically

isolated from the DC Source.  The 48 VDC source is to be reliably connected to
earth 

(ground).

Equipment grounding is vital to ensure safe operation.

Prior to installation, use a voltmeter/ohmmeter to check the wiring for the
presence of earth ground.

Required Disconnect

A readily accessible disconnect device as part of the building installation shall be
incorporated into the fixed wiring.  The disconnect device 

(a 48 VDC, 15 or 20A

circuit breaker or switch

) must be included in the ungrounded supply conductor.

Overcurrent protection must be a 15 or 20A,  48 VDC fuse or circuit breaker.

CAUTION:  Ensure that the power source is NOT powered when connecting it to
the SPS-1872-xx external power supply.  Failure to observe this caution could
result in damage to, and subsequent failure of, the SPS-1872-xx.

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing or servicing the power supply module.  Failure to
observe this caution could result in damage to, and subsequent failure of, the
power supply module.

WARNING:  The SPS1872 must be attached to a limited current circuit with a
non-hazardous energy level of less than 240VA and be located in a restricted
access area. Failure to observe this warning could result in an electrical shock.

techsupport@transition.com

-- Click the 

“Transition Now”

link for a live Web chat.

3

Installation

-- Continued

SPS-1872-SA 

(Stand Alone)

NOTE:

The SPS-1872-SA external power supply is shipped with four (4)

attached feet.

1.

Place on any well-ventilated table-top or shelf with access to a power
source with a range between 18-60 VDC or 24-30 VRMS.

2.

Connect the barrel connector on the SPS-1872-SA to the power port of
the media converter or similar device 

SPS-1872-CC / SPS-1872-PS / SPS-1872-DPS

The SPS-1872-CC, SPS-1872-PS, and SPS-1872-DPS are designed for three
different types of media converters.  Each has slightly different dimensions and
each has the barrel connector in a different location to ensure that each power
supply is used for the proper application.  

Note the differences between the three devices below:

SPS-1872-CC

SPS-1872-PS

SPS-1872-DPS

3.125 in.

3.375 in.

3.375 in.

The SPS-1872-CC is designed for the
Transition Networks Conversion
Center™ media converter.

Note that this device is slightly narrower
than the other two devices.

The SPS-1872-PS is designed for the
Transition Networks PointSystem™
media converter.

The SPS-1872-DPS is designed for the
Transition Networks Dual
PointSystem™  media converter.

Note that this device is taller than the
other two devices.

Summary of Contents for SPS-1872-CC

Page 1: ...and industrial applications The 24 30 VRMS input allows for installation of the SPS 1872 xx in remaining industrial applications as well as HVAC and building control environments The piggy back feature of the SPS 1872 CC SPS 1872 PS and SPS 1872 DPS allows it to physically attach to the media converter chassis and eliminate the power cable between the power supply and the media converter User s Gu...

Page 2: ...re to observe this caution could result in damage to and subsequent failure of the power supply module WARNING The SPS1872 must be attached to a limited current circuit with a non hazardous energy level of less than 240VA and be located in a restricted access area Failure to observe this warning could result in an electrical shock techsupport transition com Click the Transition Now link for a live...

Page 3: ...he two devices are connected The screw holes on the left and right sides should align 3 Secure the two devices together by replacing the two screws on either side of the SPS 1872 PS 4 24 Hour Technical Support 800 260 1312 International 952 941 7600 SPS1872 xx SPS 1872 PS TN PointSystem media converter SPS 1872 CC TN Conversion Center media converter techsupport transition com Click the Transition...

Page 4: ...RNING The SPS1872 must be attached to a limited current circuit with a non hazardous energy level of less than 240VA and be located in a restricted access area Failure to observe this warning could result in an electrical shock techsupport transition com Click the Transition Now link for a live Web chat 7 Maintenance Replacing the Fuse CAUTION The external power source MUST BE POWERED OFF when rep...

Page 5: ...d according to Belcore 834 000 hours with typical load at 50 C ambient temperature calculated according to MIL HDBK 217F Environment Tmra 0 to 50 C 32 to 122 F Storage Temp 20 to 85 C Humidity 5 to 95 non condensing Altitude 0 to 10 000 feet Manufacturer s rated ambient temperature Warranty Lifetime techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specificat...

Page 6: ...e European Parliament and of the Council of 27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this document CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public ...

Page 7: ...ir respective owners Copyright Restrictions 2003 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33266 E ...

Reviews: