reader the user  can‘t  exit  from  the  controller  inside,  also,  the  user  can‘t  enter  in  and 
exit continuously. 

 

 

10.5 Anti-Pass Back for 2 doors 

 

See Figure

 

4 for the Connection Diagram. Door 1 with one DOLCSAW10KH and Door 2 with 

one DOLCSAW10KH, set DOLCSAW10KH on Door 1 as the Anti-Pass Back Auxiliary unit (3 2 #), 
and set the other DOLCSAW10KH

on Door 2 as the Anti-Pass Back Master unit (3 1 #). Then 

they build up a  

  two doors anti-pass back system, which is normally used for a parking lot…etc

 

 
The operation and function is shown below:

 

5.1 Set the needed function and enroll the User Cards from DOLCSAW10KH Anti-Pass Back   
Master unit on Door 2

.     

 
5.2 With the valid user card, the user can only enter in from Door 1, and exit from Door 2. On 
the  other  hand,  without  entering  record  from  the  Auxiliary  unit,  the  user  can t  exit  from  the 
Master unit or Auxiliary unit, also, the user can t enter in and exit continuously. 

 

     

10.4 Anti-Pass back for single door (3 1 #) 

See Figure 1 for the connection diagram. Install one Wiegand reader (or a DOLCSAW10KH

 

without user information  as reader) outside the door, connecting to one DOLCSAW10KHController
inside the door which acts as the Anti-Pass Back Master unit. Of the two devices, they build
up an anti-pass backsystem  for single door. The operation and function is as below: 
4.1  Set  the  needed  function  and  enroll  the  User  Cards  on  the  inside  DOLCSAW10KH  Anti-
Pass Back Master  unit.   
4.2 With the valid user card, the user can only enter the door from the outside reader, and exit 
from the inside DOLCSAW10KH

 

 Controller. On the other hand, without entering record from the

11

 

Summary of Contents for DOLCSAW10KH

Page 1: ...Model DOLCSAW10KH A Waterproof Stand Alone Proximity Reader DOLCSAW10KH User Manual...

Page 2: ...defualt factory mastercode Note In order to start programming the master user must enter the programming mode Enter programming mode To exit the programming mode 888888 New code Repeat new code 0 1 R...

Page 3: ...t The block enrollment function allows you to enroll a maximum 10 000pcs HID cards or EM cards at a time within 10 minutes These features make the DOLCSAW10KH easy in operation safe and reliable it is...

Page 4: ...Alarm output load Max20A Adjustable Door Relay Time 00 99 seconds Adjustable Alarm Time 0 3 minutes Wiring Connections Electric Lock Exit Button DOTL External Alarm Manager card Two Dimensions 4 1 8...

Page 5: ...onnect to the positive pole of the lock and alarm equipment Connection Diagram Note Do not power on until all wiring has been completed 7 To Reset to Factory Default Power off use the supplied Contact...

Page 6: ...anager Delete Card Manager delete card Read Card Manager delete card Cards can be deleted continuously B By Remote control Enter into the programming mode firstly To Enter the programming mode Manager...

Page 7: ...can enroll maximum 10 000pcs cards at a time within 10 minutes 8 8 digits Card number Card quantity Card quantity is between 1 10 000 Of the 8 digits card number for HID card they are the 3 digits of...

Page 8: ...lock if the door is forced open or if the door is opened after 120 seconds of the electro mechanical lock not closed properly the inside buzzer and alarm output will both operate To disable door open...

Page 9: ...H Cards are required to be added at the external reader except where an external ID reader is used in this case cards can be added at either reader or controller See figure 1 Figure 1 10 2 DOLCSAW10KH...

Page 10: ...must be the same including the master code See figure 3 Figure 3 Green White Grey Yellow Brown Red Black Blue Purple Orange Green Indoor J1 J1 DOLCSAW10KH controller 1 DOLCSAW10KHcontroller 2 Outdoor...

Page 11: ...Door 1 and exit from Door 2 On the other hand without entering record from the Auxiliary unit the user can t exit from the Master unit or Auxiliary unit also the user can t enter in and exit continuo...

Page 12: ......

Reviews: