6. Wiring
No
Color
Function
Description
1
Green
D0 Wiegand output, input signal wire D0
2
White
D1
Wiegand output, input signal wire D1
3
Grey
ALARM+ connecting to the negative pole of the alarm equipment
4
Yellow
OPEN
To connect to one part of Exit Button
5
Brown
D_IN
Door Contact input,
6
Red
12V
(+) 12Vdc Positive Regulated Power Input
7
Black
GND
(-) Negative Regulated Power Input
8
Blue VSS
the negative pole of the controller, connect to the other part of Exit
button and door contact
9
Purple
L-
Connect to the negative pole of the Lock
10
Orange
L+/Alarm+
Connect to the positive pole of the lock and alarm equipment
Connection Diagram
Note: Do not power on until all wiring has been completed
7.
To Reset to Factory Default
Power off, use the supplied Contact Pin to short out the 2P socket on the main board, then
power on, if successful, the beeper will beep twice, the LED shines in orange, remove the
Green
DOLCSAW10KH
J1
Special Power Supply
Common Power Supply
DC12V/3A
Alarm
Lock
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
door detecting switch
door detecting switch
Fail-safe lock
Fail-secure lock
exit btn
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
Green
J1
Alarm
DC12V/3A
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
exit btn
PUSH NC COM NO
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
5