User Manual

Body Fat Analyzer

GBF-1319-B

version:1.0

Please do read the user manual carefully and thoroughly so as to ensure 

the safe usage of this product, and keep the manual well for further 

reference in case you have problems.

Thank you very much for selecting the Transtek Body Fat Analyzer 

GBF-1319-B. 

GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD

Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch Development 

District, Zhongshan, Guangdong, 528437, China
TEL:86-760-88282982  www.transtek.cn

Contains FCC ID:OU9AW2540-LS

Summary of Contents for GBF-1319-B

Page 1: ...the manual well for further reference in case you have problems Thank you very much for selecting the Transtek Body Fat Analyzer GBF 1319 B GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO LTD Zone A 5 F In...

Page 2: ...Your Scale Weight Only Operation Start Measuring First Measurement Daily Measurement Data Transmission Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specificati...

Page 3: ...THE OPERATION GUIDE MUST BE READ Symbol for MANUFACTURER Symbol for ENVIRONMENT PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exi...

Page 4: ...a flat hard surface Soft surface such as carpet will affect the performance of the scale Step onto the platform with bare feet Stand still and keep full contact with the electrodes until the measurem...

Page 5: ...ercentage Foot Centimeter Age Male Male Athlete Female Female Athlete User ID Range from P1 to P8 LCD Display General Instructions Initial Start Up Insert the Batteries Open the battery door in the ba...

Page 6: ...r Up With the advanced Bluetooth 4 0 technology applied the mobile or portable equipments which are equipped with Bluetooth function in line with BLE Technical Specifications established by global org...

Page 7: ...o confirm Gender Athlete Mode An athlete is defined as an adult who is involved in intense physial activity of approximate 12 hours per week and who has a resting heart rate of approximately 60 beats...

Page 8: ...automatically turn off after a few seconds Note The weight value won t be saved in the scale and won t be transmitted to the APP 1 Press the platform centre and remove your foot 2 0 0 will be display...

Page 9: ...LCD will only display the weight data To find out the solutions please refer to Troubleshooting for more details STEP 1 Step on the platform barefooted when the LCD displays 0 0 15 14 First Measureme...

Page 10: ...will disappear after successful data transmission and you may check your personal health data stored in your iPhone If the data transmission fails the symbol will remain The pending measurement data w...

Page 11: ...e Solution Incorrect posture Abnormal measuring results Too high OR Too low OR Huge difference between two recent measurement Please step on the platform barefooted and stand still The device is locat...

Page 12: ...h most similar data Please assign a User ID following the instruction in Set Up Your Profile The user fails to select the User ID from what the system found Please assign a User ID following the instr...

Page 13: ...ent Temperature 10 to 40 Humidity 90 RH Storage Environment Temperature 20 to 55 Power Source 4 5V 3xAAA Batteries Turn on Method SENSE ON technology Auto OFF The scale will turn off after about 10s i...

Page 14: ...rference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for...

Page 15: ...pproximately 40 of total body weight Approximately 30 of total body weight Bone Mass Percentage Source Rico et al 1993 The average bone mass percentage for both men and women is between 4 to 5 EMC Gui...

Page 16: ...MS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment guidance Conducted RF I...

Page 17: ...distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitters r...