EMC GUIDANCE

This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will
not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more
of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.

FCC Statement

FCC ID:OU9TMB1490B2

FCC STATEMENT

28

Summary of Contents for TMB-1490-BS

Page 1: ...490 BS Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems version 1 0 Guan...

Page 2: ...ords Delete the Records INFORMATION FOR USER 18 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 20 What are systolic pressure and diastolic pressure What is the standard blood pressure classifi...

Page 3: ...rd and using Measurement Principle This product uses the Oscillometric Measuring method to detect blood pressure Before every measurement the unit establishes a zero pressure equivalent to the air pre...

Page 4: ...high frequency HF surgical equipment at the same time CAUTION Warning This device is not AP APG equipment Do not use the device where flammable anesthetic are present or in environments mixture with...

Page 5: ...t three records Bluetooth icon The bluetooth icon blinks when the bluetooth is working Pulse in beats per minute Pulse display Deflation symbol The cuff is deflating Indicate it is in the memory mode...

Page 6: ...t use different types of batteries together Do not dispose the batteries in fire Batteries may explode or leak Remove batteries if the device is not likely to be used for some time Worn batteries are...

Page 7: ...right year press SET to set down and turn to next step 4 Repeat steps 2 and 3 to set the MONTH and DAY 5 Repeat steps 2 and 3 to set the TIME FORMAT between 12h and 24h Pul min MEMORY TIME DATE S M ST...

Page 8: ...that the cuff is at the same level as your heart Turn your palm upwards Sit upright in a chair and take 5 6 deep breaths Rest for 5 minutes before first measuring Wait at least 3 minutes between meas...

Page 9: ...nd it will finish the whole measurement save and transmit the measurement data for the desired user Take User A for example Install the APP and register an account Then set your personal information G...

Page 10: ...min MEMORY TIME DATE S M START STOP Recall the Records 2 Press the MEM or SET to get the record you want The most recent record 1 is shown first Each new measurement is assigned to the first 1 record...

Page 11: ...ase Avoid dusty and unstable temperature environment Do not attempt to clean the reusable cuff with water and never immerse the cuff in water Tips for Measurement Within 1 hour after dinner or drinkin...

Page 12: ...r Heartbeat Detector CAUTION The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heart beat was detected during measurement Usually this is NOT a cause for...

Page 13: ...e measurement Relax for a moment and then measure again Relax for a moment and then measure again The measurement process does not detect the pulse signal Loosen the clothing on the arm and then measu...

Page 14: ...re operating normally Warning Use of accessories transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions...

Page 15: ...ngle phase at 0 0 UT 250 300 cycle Conduced RF IEC61000 4 6 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz and 80 MHz 80 AM at 1 kHz 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur...

Page 16: ...led and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If t...