LYNX Plus Programming Manual Rev 2.1c
Page
119
06. Loud Bell
Refer to Program 06
to assign Relay to operate for a Loud Bell.
IP
Value
Value Description
35-tk-06
0
No Operation.
35-tk-06
1
Relay on Motherboard / ACP will be activated when the trunk is ringing.
Note:
The system does not provide any voltage from the assigned relay. A separate ring voltage and ring device
will need to be provided by the installer
07. Inward Line Ringing Method Assignment (Day)
As described in Program 01-tk-IP, there are four ringing methods plus a Private line setting:
COMMON AUDIBLE RINGING
Ring all assigned Extensions simultaneously.
LINEAR RINGING
Attempt to ring the first available Extension in order of the Extensions assigned in
Program 01-tk
if in Day
Service or
Program 02-tk
if in Night Service
.
CIRCULAR
RINGING
The first incoming call on each trunk rings the first assigned extension, the 2nd incoming call on that trunk
rings the next assigned extension, etc.
HUNT
Provide the ability to route calls to a main answering position and provide an overflow capability so that
backup answering stations can be automatically added as necessary. If an incoming line rings an
extension which is busy or does not answer within the assigned Hunt Time (Program
05-08-01
,) the call
will ring the next available extension assigned in the hunt group (Up to 16). If the next ringing station is
busy then the call will immediately move to the next ring assigned extension but if the station does not
answer then the call will wait for the Hunt time and then ring the next assigned extension. Once the ring
assignment has passed a station which is busy then it will provide Off Hook Busy Remind signal and when
the station is free if the call is still unanswered the station will commence ringing for that call. Stations
which do not answer a call will also continue to ring until the call is answered.
PRIVATE
This is for an incoming private line. The station that owns this private line can set call forward (All, Busy,
No Answer) for this private line to the Voice Mail Port (See Program
43- ST-02
) or off premises.
IP
Value
Value Description
35-tk-07
0
Day - COMMON AUDIBLE
35-tk-07
1
Day - LINEAR
35-tk-07
2
Day - CIRCULAR
35-tk-07
3
Day - HUNT
35-tk-07
4
Day – PRIVATE