LYNX Plus Programming Manual Rev 2.1c
Page
35
Access Control Telephone/Door Phone – ACP/DPU
A cable cover is provided with the KSU. Station cables enter from bottom of the KSU. Remove the
cover as required and route the station cable through the hole. Terminate the station wires with the
connectors that are provided. The stations will connect to the KSU as shown on the main panel
(above) on connector locations ST1~ST4 (port11~port14)
Connect Tip/Ring terminals from KSU (G1K-MBU) to the ACP/DPU connector (6 contacts).
There is no polarity requirement on Tip and Ring.
Connect Relay for applications such as door open to the ACP/DPU connector (6 contacts).
Connect Sensor for applications such as door open alarm to the ACP/DPU connector (6 contacts).
Mount ACP connector on to ACP/DPU itself.
Select the 1
st
station jumper as shown in diagram below.
Mount ACP/DPU on the wall.
CAUTION!:
Avoid shorting Tip and Ring together. It may damage the G1K-MBU board.