LYNX Plus Programming Manual Rev 2.1c
Page
51
Program 05-02-IP : System Timing Parameters – 02
05-02-IP SYS PAR
5 5 1 2 1 0 2 4
IP=Item Pointer (01-08)
Value for each item
IP
Value
Default
Item Description
01
0-9
5= 15 Sec.
SLT Dial Tone Timeout
02
0-9
5= 15 Sec.
SLT Inter-Digit Timeout
03
1-9
1= 10 Sec.
Auto Redial Access Time – PSTN Lines
04
0-9
6=1000 ms. SLT Release Signal Time
05
0-9
5= 800 ms.
PSTN Lines Flash Time - Key Phone & Analog Phone
06
0-9
0= 70 ms.
SLT Hold Signal Time
07
0-9
2= 240 ms.
Ring On Time
08
0-9
6= 6 Sec.
Ring Off Time
01. SLT Dial Tone Timeout
This parameter is for SLT (Single Line Telephone). If a key of SLT is not pressed before this assigned
timer expires when Dial Tone is given, a Busy Tone will be heard.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-02-01
0
2
4
6
8
15
30
60
120
254
Sec.
02. SLT Inter-Digit Timeout
This parameter is for SLT (Single Line Telephone). If the interval between digits dialled exceeds this
assigned timer, a Busy Tone will be given.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-02-02
0
2
4
6
8
15
30
60
120
254
Sec.
03. Auto Redial Access Time – PSTN Lines
This parameter sets the waiting timer after system redial the telephone number in Auto Redial feature. If
the call is not answered before this timer expired, system will hang up and wait for the Auto Redial Pause
Time – Program 05-05-08, and then try to redial again. ISDN lines will hang up immediately if the called
number is busy. Refer to Program 05-05-07 Auto Redial Trials for number of redial attempts
IP \ Value
1
2
3
4
5
6
7
8
9
Unit
05-02-03
10
20
30
40
50
60
70
80
90
Sec.
Summary of Contents for Lynx DK6 Series
Page 1: ...Telephone System Master Programming Manual Rev 2 1c ...
Page 2: ......
Page 24: ...Page 24 ...
Page 34: ...Page34 ...
Page 40: ...Page40 ...
Page 44: ...Page44 DK6 Key Telephone Key Layout 18 Button DK7 Key Telephone Key Layout ...