Page
96
Program 06-IP : Relay Assignment
06-St-01 Relay
00
St= Station Number
Value for each Item
St
Item Value
Relay Description
000
00-06, 10, 11-18 Relay of Motherboard (Optional)
xxx
00-06, 10, 11-18 Relay of ACP (extension: xxx)
Description:
Relays on the Motherboard and ACP are Dry-contact type relays. The relay provides no power only a
switching function.
The maximum limit for the voltage and current for the relay contacts is 24Vdc or 90Vac at 1 A.
They are only designed for low voltage control circuits. All Relays are Normally Open contacts and will
close on activation of the function for which they have been programmed.
When the St is 000, it means the relay on the motherboard. When the St is a valid station number, it is the
relay on the ACP corresponding to that station number..
Assign the required Relays to one of the following functions.
Item Value
Function
00
No Operation
01
Music On Hold
02
Door open
03
Reserved for future use
04
Trunk loud bell
05
Station loud bell
06
System Alarm
10
All Paging [#0]
11
External zone page Group - 1 [#31]
12
External zone page Group - 2 [#32]
13
External zone page Group - 3 [#33]
14
External zone page Group - 4 [#34]
15
External zone page Group - 5 [#35]
16
External zone page Group - 6 [#36]
17
External zone page Group - 7 [#37]
18
External zone page Group - 8 [#38]