Digital Telephone System Parameters
Note 1: The values listed are only suggestions for these parameters. The
actual configuration of these parameters depends on whether the TMS is
acting as Automated Attendant or calls are being answered by a live opera-
tor. These values for these parameters will also be influenced by the val-
ues set in 46-stn-07 (Call Forward No-Answer to a Pre-assigned Hunting
Group) and 78-st-04 (Call.Forward Busy to a Pre-Assigned Hunting
Group).
The following programming changes will be determined by the extension
number and circuit number (card-circuit). Please refer to the entries you
made on page 4 of this document.
Item
Description
Plug-N-Play
05-01-08
Call Forward No Answer Trans-
fer Time
1=20 seconds
Note 1
05-01-05
Busy Reminder Tone Interval
6=30 seconds
05-02-01
Single Line Telephone Dial
Tone Timeout
5=16 seconds
05-02-02
Single Line Telephone – Inter
Digit Timeout
5=16 seconds
05-02-04
SLT Release (Disconnect)
6=1000 ms
05-02-06
SLT Hold Signal (Flash Timer)
4=300 ms
05-03-07
Dial Tone Options
0=Normal
05-04-08
Message Waiting for Single
Line Telephones
0=disable message
waiting ringing
05-06-01
Transfer Recall – Busy
4=30 seconds
Note 1
05-06-02
Transfer Recall - No Answer
4=30 seconds
Note 1
05-08-01
CO Hunt Interval
3=6 seconds
05-08-03
SLT Busy Remind Tone
0=Disable
05-08-05
SLT Programming Access
Code First Digit
7=7
05-09-03
CO Loop Disconnect
(Calling Party Control)
4=320
milliseconds
05-10
Voice Mail digit string
dddddddd
05-12-02
Mute CO trunk on disconnect
(open loop)
1=Mute on Open
Loop
05-12-05
VM Integration Type
7=Digit+ Extension,
no CO codes sent