Hardware Installation
Take the following steps to set up your TR-49.
Site Selection:
Before installation, determine the TR-49 unit’s location. Proper placement of the unit
is critical to ensure optimum radio range and performance. You should perform a Site Survey to
determine the optimal location. Ensure the CPE is within line-of-sight of the Access Point.
Obstructions may impede performance of the unit.
Tools Required to Install
•
One 3/8 wrench
•
One 3/4 wrench
•
One RJ-45 crimper
•
A suitable length of Cat 5 cable to bring the signal from the unit to the Power over Ethernet
Adaptor
•
2 RJ-45 Jacks
Before installing, you must determine if the unit will be in the horizontal or vertical orientation. The
TR-49 model can be mounted in either orientation. The Ethernet boot should always be placed so
that the cable runs toward the ground for maximum environmental protection.