VI. d - CONFIGURATION PARAMETERS
Parameter Configuration:
• To get access to the parameter configuration menu,
press button
and for 5 seconds.
• With button or select the parameter to be
modified.
• Press button to display the value.
• By keeping button pressed, use button or to
set the desired value.
• When button is released, the newly programmed
value is stored and the following parameter is displayed.
• To exit from the setup, press button or wait for 30
seconds.
VI. e - TECHNICAL DATA
Power supply
BD1-28....W
100-240Vac ±10%, 50/60Hz, 3W
Relay output max loads (240Vac)
BD1-28..S/T..-.
BD1-28..Q/R..-.
Compressor
16A resistive
12 FLA 48 RLA
12A resistive
12 FLA 48 RLA
Evap. Fan
16A resistive
4 FLA 12 RLA
8A resistive
4 FLA 12 RLA
Defrost
16A resistive
4 FLA 12 RLA
16A resistive
4 FLA 12 RLA
Auxiliary loads 1
7A resistive
7A resistive
Auxiliary loads 2
7A resistive
7A resistive
Input
NTC 10KΩ@25°C
LAE Part No. SN4...
Measurement Range
<0.5 within the measurement range
Operating Conditions
-10... +50°C; 15%...80% r.H.
CE (Approvals and Reference Norms)
EN60730-1; EN60730-2-9; EN55022 (Class B); EN50082-1