VII. INTELA-TRAUL
®
(continued)
-12-
Listed below are the available parameters in the order they appear, using the down arrow key on the
controller. You can use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High*
Defrost Lockout 2
Thermostat Set Point Low
Defrost Lockout 3
Temperature Scale*
Defrost Lockout 4
Audible Alarm Style*
Dew Point Compensation Factor*
Time (24-hour clock)*
Room Temperature Offset
Date (month - day - year)*
Evaporator Coil Sensor
Daylight Savings *
Discharge Line Sensor
Defrost Lockout 1
Start Manual Defrost
VII. g - CUSTOMER SERVICE PARAMETERS:
VII. h - ADJUSTING THE THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will
range from -3
°
F to 0
°
F (-19
°
C to -18
°
C) and refrigerators will range from 36
°
F to 40
°
F (2
°
C to 4
°
C)
for this parameter setting. This parameter is preset at the factory and does not have to be adjusted
unless the customer chooses to do so. Note: Set Point Low and Set Point High
cannot
be set to the
same temperature. There will be at least 1-2 degree difference between the two settings.
Follow the instructions to enter the customer access code on page 11. When the control
display reads Thermostat Set Point High. Press the set button .
Use the arrow keys to adjust the temperature to your desired setting.
When the display shows the temperature you want press the set button .
The display will then read Thermostat Set Point High.
You can use the up or down arrow keys to scroll to the next parameter
or press the alarm cancel button to exit .
SET
SET
)
)
)
*Available on Hot Food units.