background image

XV. WARRANTY INFORMATION

-25-

STANDARD DOMESTIC WARRANTY

TRAULSEN warrants new equipment to the original purchaser, when installed within the United States against defective material and
workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN will repair or replace, at its option,
including service and labor, all parts found to be defective and subject to this warranty. The compressor part is warranted for  an
additional four (4) years. During this period TRAULSEN will supply replacement compressor(s) if deemed defective, however all
installation, recharging and repair costs will remain the responsibility of the owner.
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of God, terrorism,
attempted repairs, improper installation by unauthorized persons, and does not apply to food loss.
For Traulsen units purchased with a remote feature, standard warranty will apply only to those components contained within the unit to
the point of connection of the refrigeration lines leading to the remote condenser.
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN, INCLUDING BUT NOT LIMITED
TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR
CONSEQUENTIAL OR SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE,
OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY
OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE, OPERATION OR USE OTHER THAN AS
STATED HEREIN.

INTELA-TRAUL

®

 CONTROL WARRANTY

TRAULSEN warrants to the original purchaser of the INTELA-TRAUL

®

 control when installed as part of the Refrigeration/Hot Food

Equipment manufactured and sold by TRAULSEN, to be free of defects in material and workmanship under normal service and use for
a period of two (2) years from the date of installation. Under this warranty statement, TRAULSEN will repair or exchange at TRAULSEN

S

discretion, F.O.B. factory, any part of said control, which proves to be defective. Inspection by the TRAULSEN Service Department of
parts claimed defective shall be final in determining warranty status. The warranty is to include repair or exchange of any defective
In-Warranty control or part(s) of said control for:

Part(s) – Any TRAULSEN INTELA-TRAUL

®

 supplied part(s) found to be defective.

Labor – The labor charges from a TRAULSEN certified service agent to effect the repair or exchange of the defective part(s).

Defective Part Return

 – All claimed defective part(s) must be returned to TRAULSEN for defect validation within 30 days from the

date of the repair. Failure to return all claimed defective part(s) to TRAULSEN will invalidate the warranty claim, this warranty
statement, and forfeit payment for those repairs effected.
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of God, terrorism,
attempted repairs, improper installation by unauthorized persons, and does not apply to food loss, and will not apply if said equipment
is located outside The United States.

INTERNATIONAL COMMERCIAL WARRANTY

TRAULSEN warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free from defects in material and workmanship under normal
use and service for a period of one (1) year from date of shipment. Under this warranty, TRAULSEN will reimburse the purchaser for the replacement of any part of said
equipment (excluding dryers & refrigerant gas) which then proves to be defective.  This warranty does not apply to damage resulting from fire, water, burglary, accident,
abuse, misuse, transit, acts of God, terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss.

TRAULSEN

S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date of original installation not to exceed Fifteen (15) months from

date of shipment from factory, TRAULSEN:

will replace, F.O.B. factory, any defective parts normally subject to warranty.

will not cover the cost of packing, freight or labor such costs being the sole responsibility of the dealer.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES

TRAULSEN

S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON REMOTE MODELS.

Summary of Contents for R & A Series

Page 1: ...ed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possib...

Page 2: ...sting Thermostat Set Point Low Page 13 j Changing The Temperature Scale Page 13 k Setting The 24 Hour Clock Page 14 l Setting The Date Page 15 m Setting Daylight Savings Time Page 15 n Starting A Manu...

Page 3: ...own on its front side or back However if you must please be certain to allow the unit to remain in an upright position afterwards for 24 hours before plugging it in so that the compressor oils and ref...

Page 4: ...breaker strip near the bottom door opening Next loosen the thumb screws located along the floor at the threshold Place the ramp s on top of the loosened thumb screws and secure tabs on each end to br...

Page 5: ...nits serial tag It is the responsibility of the installer to specify and supply the correct size compressor s based upon this information and on site requirements Refrigerant line installation III INS...

Page 6: ...ontrols function upon termination of a defrost cycle is two fold First to prevent blowing warm air into the food storage area Second to prevent any condensation on the defrost coil from being blown in...

Page 7: ...SHELVES For shelves mounted on pins first select the desired location and remove the white plastic covers in the interior back and sides by rotating them counter clockwise Remove the shelf pins by ro...

Page 8: ...please check the following Is the electrical cord plugged in Is the fuse OK or circuit breaker on Is the power switch ON If after checking the above items and the unit is still not operating properly...

Page 9: ...refrigerator and freezer models only Note The 24 hour clock and the date must be set for the above information to be recorded at the correct time and date 6 Communication Ability An RS485 port port i...

Page 10: ...t lockouts or are retrieving the information from the data storage memory See Setting The 24 Hour Clock page 12 and Setting the Date page 15 Door Open The door open icon on the face of the control wil...

Page 11: ...HORN 337 60069 00 337 60070 00 HOLDER CLIP 377 60038 00 INTELA TRAUL VERTICAL CONTROLLER 337 60090 00 337 60091 00 337 60092 00 337 60098 00 Hot Food Units INCLUDES ALL SHOWN HORN DISCHARGE LINE HOLD...

Page 12: ...security code 0 A 1 and the following instructions Press the set button The display will read Customer Service Access Press the set button The display will show three zeros with the left zero flashing...

Page 13: ...ature range Typically freezers will range from 3 F to 0 F 19 C to 18 C and refrigerators will range from 36 F to 40 F 2 C to 4 C for this parameter setting This parameter is preset at the factory and...

Page 14: ...re to your desired setting When the display shows the temperature you want press the set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to...

Page 15: ...5 00 a m H11 11 00 a m H17 5 00 p m H23 11 00 p m H06 6 00 a m H12 12 00 p m H18 6 00 p m H24 12 00 a m Follow the instructions to enter the customer access code on page 11 When the control displays T...

Page 16: ...y is displayed press the set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter press the alarm cancel button to exit VII...

Page 17: ...he set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter or press the alarm cancel button to exit The defrost icon will...

Page 18: ...00 a m 120 12 00 p m 180 6 00 p m 240 12 00 a m 063 6 30 a m 123 12 30 p m 183 6 30 p m 243 12 30 a m 070 7 00 a m 130 1 00 p m 190 7 00 p m 010 1 00 a m 073 7 30 a m 133 1 30 p m 193 7 30 p m 013 1 3...

Page 19: ...ay will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter or press the alarm cancel button to exit VII q ADJUSTING THE ROOM TEMPERATURE OFFSET T...

Page 20: ...arrow keys to scroll between for the 3 Second Audible Alarm Burst or for Continuous Audible Alarm When the display shows your choice of style press the set button The display will then read thermosta...

Page 21: ...please note that this feature is not available on versions of the control manufactured prior to September 2000 or if an alarm warning condition is present use the alternative ON OFF activation method...

Page 22: ...oor was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature c INTELA TRAUL setting too high readjust per instructions on p...

Page 23: ...Jewelers type door lock for sliding glass door model Hinge Cam 344 28488 00 Replacement hinge cam Hinge Cover 344 28486 00 Replacement hinge cover Hinge Spring Assist SER 29021 03 Alternative hinge s...

Page 24: ...of a Traulsen refrigeration product resulting in corrosion Avoid use of these on or around a Traulsen refrigeration product if at all possible 4 PROLONGED CONTACT WITH FOOD PRODUCT Many food products...

Page 25: ...when it first becomes visible When rust occurs do not allow it to remain for any period of time and remove it using the following method STEP ONE Use a lightly abrasive compound free of harmful chlori...

Page 26: ...ry any part of said control which proves to be defective Inspection by the TRAULSEN Service Department of parts claimed defective shall be final in determining warranty status The warranty is to inclu...

Page 27: ...ock 8 INTELA TRAUL 5 8 20 J K L Legs Installing The 2 3 Light Bulb Replacing The 7 Light Cover 7 Louver Assembly 5 6 M Manual Defrost Cycle 16 N O P Power Supply 4 R Remote Installation 3 Return Autho...

Page 28: ...lue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2004 Traulsen All R...

Reviews: