10
IV. SMART CHILL CONTROL
IV.h
–
FACTORY MENU ACCESS (CONT):
4. Press and release the TOP LEFT, TOP RIGHT, and
BOTTOM RIGHT buttons, all three simultaneously.
5. The display will advance to the “
FACTORY
SETTINGS VERSION #.##
” screen.
You now have
access to the
“FACTORY MENU”
. (See section IV.I
–
Factory Menu Navigation, for more information on the
Factory Menu).
IV.h.3
–
FACTORY MENU ACCESS
Exercise extreme caution at all times.
CAUTION: Electro-static discharge will damage the
control board. Use an anti-static grounding kit when
servicing the computer control box.
1. Remove thumb screws and control cover.
2. Remove five phillips head screws from control
mounting brackets to access the rear of the control.
3. Disconnect power to the control by unplugging the 3
pin connector (wire color: red, white, black) labeled
J12, PWR on the mother board.
4. Locate the push button labeled FACT on the control
mother board.
5. Push and hold the FACT button, then reconnect the 3
pin connector, J12 PWR, while still holding the TEST
button. Once power has been restored release the test
button and check control display. You should now
have access to the “FACTORY MENU” (See section
IV.I
–
Factory Menu Navigation, for more information on
the Factory Menu).
IV.i - NAVIGATING THE FACTORY MENU
i.1 Reset and Serial Number Entry
Upon accessing the Factory Menu you will be at the
Reset and Serial Number Entry screen. Here can reset
all default settings by pressing the button labeled
“RESET”. After doing this you may
need to re-enter the
serial number of the unit. (Note: serial number is for
reference only and is not critical to unit function).
To enter the serial number use the
to change the
value of the current digit. Press the
to advance to
the next digit. For serial numbers with 5 digits between
the T and the A leave the digit after the T at 0. Press
“NEXT” to advance to the Printer Selection Screen.
i.2 Printer Selection
The Printer Selection Screen allows you to turn on or
off specified printers. Depending on revision you
options may differ slightly. Most versions only allow
the Label printer to be turned on or off. Version 2.11 or
higher will allow for both Label and Record Printers to
be toggled on or off. To turn a printer on or off select
button to the left or right of the printer you wish to edit.
“YES” to activate printer “NO” to deactivate printer.
Press “NEXT” to advance to the
Refrigeration Settings
Screen or “BACK” to return
to the previous screen.
i.3 Refrigeration Settings
The Refrigeration Settings Screen allows you to adjust
the following settings
Blast or chilling temperature differential
Holding or maintenance temperature
differential
Compressor Anti Short cycle
To adjust any of these settings use the up or down
arrows next to the appropriate parameter.
Press “NEXT” to advance to the Defrost Settings
Screen or “BACK” to return to the previous screen.
85
J12
PWR
FACT
FACTORY SETTINGS
VERSION 2.11
S/N: T 0 0 0 0 0 0 A 0 0
RESET NEXT
RECORD PRINTER [YES]
LABEL PRINTER [NO ]
BACK NEXT
BLASTING DIFF [4 ] F
HOLDING DIFF [3 ] F
ANTI-SHORT [1 ]
BACK NEXT