6
Care & Cleaning
Probes
Interior/Exterior
Condenser
fig. 2
fig. 1
Changing The Paper and/or Label Rolls
Printer Supplies:
Paper:
Traulsen P/N 400-60003-00 • Office Depot #302-224 • Staples #PMF-5233
Label:
Traulsen part number 400-60004-00. Each roll contains 225 labels.
1. Remove probes by turning the circular locking ring
which secures these inside the chiller (fig. 1).
2. Wash/sanitize probes (fig. 2). Probes can be totally
immersed in water during cleaning.
3. Allow probes to air dry before replacing in chiller.
1. Disconnect power supply.
2. Clean both interior and exterior with a soft cloth as you
would any other stainless steel surface.
3. Do
NOT
use cleansers containing chlorine.
Do
NOT
clean with anything abrasive.
Do
NOT
hose off the blast chiller.
Cleaning this is critical to insuring proper performance and
long compressor life.
1. Disconnect power supply.
2. Lift-up or remove louvers covering coil location:
• TBC5:
Front/Left
• TBC13:
Front/Bottom
• TBC1H:
Front/Top
3. Wipe coil fins clear of any dust/debris using a dry cloth
or stiff bristle brush (fig. 3).
4. Replace louvers.
5. Restore power
1. Open printer door or remove cover (older models).
2. Remove empty paper roll and spindle. Replace with
new paper or label roll. Be sure to load paper with the
thermal side facing up.
3. Lift feed roller tension arm.
4. Place paper edge on feed roller.
5. Close feed roller tension arm.
6. Press the red button to feed paper through the printer.
7. Close printer door or replace cover.
fig. 3
Feed Roller
Tension Arm
NOTE: Never place wet and/or sanitized pans or utensils inside the chiller!