background image

6

Care & Cleaning

Probes

Interior/Exterior

Condenser

fig. 2

fig. 1

Changing The Paper and/or Label Rolls

Printer Supplies:

 

Paper:

 Traulsen P/N 400-60003-00 • Office Depot #302-224 • Staples #PMF-5233

Label:

 Traulsen part number 400-60004-00.  Each roll contains 225 labels.

1.  Remove probes by turning the circular locking ring  

 

which secures these inside the chiller (fig. 1).

2.   Wash/sanitize probes (fig. 2).  Probes can be totally  

 

immersed in water during cleaning.

3.   Allow probes to air dry before replacing in chiller.

1.  Disconnect power supply.

2.   Clean both interior and exterior with a soft cloth as you  

 

would any other stainless steel surface.

3.   Do 

NOT

 use cleansers containing chlorine.

 Do 

NOT

 clean with anything abrasive. 

 

 Do 

NOT

 hose off the blast chiller.

Cleaning this is critical to insuring proper performance and 

long compressor life. 

1.  Disconnect power supply.

2.   Lift-up or remove louvers covering coil location:

•  TBC5:

 Front/Left

•  TBC13:

 Front/Bottom

•  TBC1H:

 Front/Top

3.   Wipe coil fins clear of any dust/debris using a dry cloth  

 

or stiff bristle brush (fig. 3).

4.   Replace louvers.

5.   Restore power

1.  Open printer door or remove cover (older models).

2.   Remove empty paper roll and spindle.  Replace with  

 

new paper or label roll.  Be sure to load paper with the 

 

thermal side facing up.

3.   Lift feed roller tension arm.

4.  Place paper edge on feed roller.

5.   Close feed roller tension arm.

6.   Press the red button to feed paper through the printer.

7.   Close printer door or replace cover.

fig. 3

Feed Roller 

Tension Arm

NOTE: Never place wet and/or sanitized pans or utensils inside the chiller!

Summary of Contents for TBC5

Page 1: ...TRAULSEN BLAST CHILLERS training guide Models TBC5 TBC13 TBC1H TBC1HR...

Page 2: ...efault password for the SUPERVISOR LEVEL is 1234 and for the SERVICE LEVEL is 4401 The most common operations are included inside the non password protected USER menu Table of Contents 1 TRAULSEN TBC5...

Page 3: ...uld not be placed where it is touching bone 3 With full pans of product such as casseroles locate the probe in pan center 4 In all cases probe tip should not touch pan bottom 1 It is OK to load more t...

Page 4: ...lace hot product into the blast chiller 2 Insert one of more probes into product 3 Close the door The display will begin counting down from 30 and upon time elapsing will commence chilling OPTIONAL Pr...

Page 5: ...t temp requires use of probes TIME chill cycle ends upon time elapsing does not require use of probes PRODUCT chill cycle runs based upon preloaded parameters for a given product name 6 Adjust target...

Page 6: ...equipped with the optional label printer only Repeat for additional labels 4 Press DONE for the next probe or to return to the run or idle screens The RUN screen at cycle s end The PRINT Screen Savin...

Page 7: ...clean with anything abrasive Do NOT hose off the blast chiller Cleaning this is critical to insuring proper performance and long compressor life 1 Disconnect power supply 2 Lift up or remove louvers...

Page 8: ...rmal side up c Paper does not feed or jammed Remove paper and reinstall correctly a Door out of alignment or gasket issue Check door alignment and gasket for proper seal b Door sweep worn out of adjus...

Reviews: