FREEZER
SET
INTELA-TRAUL
°
F
°
C
This parameter allows a service technician to start a defrost cycle at any time. This parameter
will override any lockout settings.
Follow the instructions to enter the customer access code on page 9. When the control
displays Thermostat Set High, press the down arrow key until the control
display reads Start Manual Defrost.
Press the set button .
The display will show (NO).
Press either arrow key (YES).
The display will show .
Press the set button .
The display will then read Thermostat Set Point High.
You can use the up or down arrow keys to scroll to the next parameter
or press the alarm cancel button to exit .
The defrost icon will be lit,
and the display will read
when the unit is in defrost.
VII. INTELA-TRAUL
®
(continued)
-15-
VII. n - STARTING A MANUAL DEFROST CYCLE:
SET
SET
)
)
)
NOTE:
Traulsen refrigerator units also have an off-cycle defrost once an hour, at which time the
control will read . This defrost is temperature terminated and can last from 3 - 10
minutes (dEF will be displayed for 22-27 minutes time).
DEFROST ICON