background image

IX. WARRANTY INFORMATION

-20-

STANDARD DOMESTIC WARRANTY

TRAULSEN & CO., INC.

 warrants new equipment to the original purchaser, when installed within the United States

against defective material and workmanship for one (1) year from the date of original installation. Under this warranty,

TRAULSEN & CO., INC.

 will repair or replace, at its option, including service and labor, all parts found to be defective

and subject to this warranty. The compressor part is warranted for an additional four (4) years. During this period

TRAULSEN & CO., INC.

 will supply replacement compressor(s) if deemed defective, however, all installation, recharg-

ing and repair costs will remain the responsibility of the owner.

This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of
God, terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss.

For Traulsen units purchased with a remote feature, standard warranty will apply only to those components con-
tained within the unit to the point of connection of the refrigeration linesleading to the remote compressor.

THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN, INCLUDING BUT NOT
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH
EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABIL-
ITY FOR CONSEQUENTIAL OR SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR
ITS SALE, OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME
FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE, OPERATION OR USE
OTHER THAN AS STATED HEREIN.

INTELA-TRAUL

®

 CONTROL WARRANTY

TRAULSEN & CO., INC.

  (

TRAULSEN

), warrants to the original purchaser of the 

INTELA-TRAUL

®

  control when

installed as part of the Refrigeration/Hot Food Equipment manufactured and sold by 

TRAULSEN

, to be free of defects

in material and workmanship under normal service and use for a period of two (2) years from the date of installation.
Under this warranty statement, 

TRAULSEN

 will repair or exchange at 

TRAULSEN

S

 discretion, F.O.B. factory, any part

of said control, which proves to be defective.  Inspection by the 

TRAULSEN

 

Service Department

  of parts claimed

defective shall be final in determining warranty status. The warranty is to include repair or exchange of any defective
In-Warranty control or part(s) of said control for:

Part(s)

 – Any 

TRAULSEN

 

INTELA-TRAUL

®

 supplied part(s) found to be defective.

Labor

 – The labor charges from a 

TRAULSEN Certified Service Agent

 to effect the repair or exchange of the defective

part(s).

Defective Part Return

 – All claimed defective part(s) must be returned to 

TRAULSEN

 for defect validation within

30 days from the date of the repair. Failure to return all claimed defective part(s) to 

TRAULSEN

 will invalidate the

warranty claim, this warranty statement, and forfeit payment for those repairs effected.

This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of
God, terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss,
and will not apply if said equipment is located outside The United States.

INTERNATIONAL COMMERCIAL WARRANTY

TRAULSEN & CO., INC.

 warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free from defects in material and

workmanship under normal use and service for a period of one (1) year from date of shipment. Under this warranty, 

TRAULSEN & CO., INC.

 will reimburse the

purchaser for the replacement of any part of said equipment (excluding dryers & refrigerant gas) which then proves to be defective. 

 This warranty does not apply

to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of God, terrorism, attempted repairs, improper installation by
unauthorized persons, and will not apply to food loss.

TRAULSEN

S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date of original installation not to exceed Fifteen (15)

months from date of shipment from factory, TRAULSEN:

will replace, F.O.B. factory, any defective parts normally subject to warranty.

will not cover the cost of packing, freight or labor such costs being the sole responsibility of the dealer.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES

TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON REMOTE MODELS.

(for Canadian warranties see domestic US warranty)

Summary of Contents for UC Series

Page 1: ...er to the model and serial number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way Traulsen Co Inc OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen UC Series Full Size Under...

Page 2: ... 10 g Customer Service Parameters Page 11 h Adjusting Thermostat Set Point High Page 11 i Adjusting Thermostat Set Point Low Page 12 j Changing The Temperature Scale Page 12 k Setting The 24 Hour Clock Page 13 l Setting The Date Page 14 m Setting Daylight Savings Time Page 14 n Starting A Manual Defrost Page 15 o Setting Defrost Lockouts Page 16 p Adjusting The Dewpoint Compensation Factor Page 17...

Page 3: ...all surfaces To remove the wooden pallet first if at all possible we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet NOTE Traulsen does not recommend laying the unit down on its front side or back However...

Page 4: ...uring freezer defrost operation heat is confined to the coil enclosure to prevent any significant rise in temperature within the food zone The fan delay con 3 III INSTALLATION continued III d INSTALLING LEGS OR CASTERS cont d Please note that Traulsen units are not designed to be moved while on legs If the unit requires moving a pallet jack or forklift should be used to prevent dam age For install...

Page 5: ... warm air into the food storage area Second to prevent any conden sation on the defrost coil from being blown into the food storage area The INTELA TRAUL control is set from the factory to terminate defrost at 20 minutes in the event of a sen sor failure This setting should never be tampered with without first consulting the factory IV c CONDENSATE REMOVAL Both refrigerator and freezer units are s...

Page 6: ...3 Phillips head screws which secure each to the cabinet face Replace the hinges in their new loca tion and replace the screws Remove the hinge cover from the door half of the hinge by sliding it downwards Next remove the hinge hard ware from the door by removing the three 3 Phillips head screws which secure each to the door Turn the door around to its new position and replace the hinge hardware to...

Page 7: ...Fig 7b Fig 7a Remove Louver Assembly VI MISC OPERATIONS cont d 6 Fig 9 Removing Power Pack ...

Page 8: ...with HAACP standards Records alarm events Records diagnostic test of each sensor every 24 hours Records failed security attempts Records door open cycles Records defrost cycles refrigerator and freezer models only Note The 24 hour clock and the date must be set for the above information to be recorded at the correct time and date Communication Ability An RS485 port is available as a means of retri...

Page 9: ...en the unit regains power after an outage To turn off the audible alarm and or clear the visual text press the alarm cancel button You must reset the clock and date if you are using any defrost lockouts or are retrieving the information from the data storage memory See Setting The 24 Hour Clock page 12 and Setting the Date page 13 System Leak The audible alarm will sound and the display will read ...

Page 10: ...e order 3 DIGIT RED LED DISPLAY HOLDER CLIP 377 60038 00 EVAP COIL NOT USED CABINET AIR NOT USED TRANSFORMER RS485 DEFROST COMPRESSOR RELAY POWER LINE IN 2 DOOR HEATER EVAP BLOWER RELAY POWER IN LINE 1 INTELA TRAUL HORIZONTAL CONTROLLER 337 60062 00 HOLDER CLIP HORN DISCHARGE LINE COIL SENSOR 337 60071 00 refrigerator freezer only CABINET SENSOR 337 60069 00 DISCHARGE SENSOR 337 60072 00 refrigera...

Page 11: ...e following instructions Press the set button The display will read Customer Service Access Press the set button The display will show three zeros with the left zero flashing Press the set button The display will show three zeros with the center zero flashing Press the down arrow key to sequence through F E d C b A 9 8 7 etc When you reach A press set The display will show zero A zero with the rig...

Page 12: ... of the desired cabinet temperature range Typically freezers will range from 3 F to 0 F 19 C to 18 C and refrigerators will range from 36 F to 40 F 2 C to 4 C for this parameter setting This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so Note Set Point Low and Set Point High cannot be set to the same temperature There will be at least 1 2 d...

Page 13: ...n the display shows the temperature you want press the set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter or press the alarm cancel button to exit VII j Changing The Temperature Scale The temperature scale determines if the temperature displayed will be in degrees Fahrenheit or degrees Celsius Follow the instruction...

Page 14: ... 5 00 a m H11 11 00 a m H17 5 00 p m H23 11 00 p m H06 6 00 a m H12 12 00 p m H18 6 00 p m H24 12 00 a m Follow the instructions to enter the customer access code on page 9 When the control displays Thermostat Set High press the down arrow key until the control display reads Clock Press the set button The display will show Hours The right two numbers will be flashing Use the arrow keys to set the ...

Page 15: ...ay is displayed press the set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter press the alarm cancel button to exit VII m SETTING DAYLIGHT SAVINGS TIME This parameter is preset at the factory to automatically adjust the 24 hour clock for Daylight Savings Time Follow the instructions to enter the customer access code ...

Page 16: ...w key YES The display will show Press the set button The display will then read Thermostat Set Point High You can use the up or down arrow keys to scroll to the next parameter or press the alarm cancel button to exit The defrost icon will be lit and the display will read when the unit is in defrost VII INTELA TRAUL continued 15 VII n STARTING A MANUAL DEFROST CYCLE SET SET NOTE Traulsen refrigerat...

Page 17: ... 6 00 a m 120 12 00 p m 180 6 00 p m 240 12 00 a m 063 6 30 a m 123 12 30 p m 183 6 30 p m 243 12 30 a m 070 7 00 a m 130 1 00 p m 190 7 00 p m 010 1 00 a m 073 7 30 a m 133 1 30 p m 193 7 30 p m 013 1 30 a m 080 8 00 a m 140 2 00 p m 200 8 00 p m 020 2 00 a m Denotes not available A lockout can not be programmed to start at 12 00 am or 12 30 am due to conflicts with other internal programs The de...

Page 18: ...meter or press the alarm cancel button to exit 17 VII INTELA TRAUL continued SET SET VII q SETTING THE AUDIBLE ALARM STYLE This parameter will allow the customer to turn on off the audible alarm feature on the INTELA TRAUL control The audible alarm is preset from the factory to OFF The customer can choose between an audible alarm that sounds for 3 seconds then automatically turns off or a continuo...

Page 19: ...s to enter the customer access code on page 9 When the control displays Thermostat Set Point High press the DOWN arrow key unit the display reads Evaporator Coil Sensor or Disharge Line Sensor or press the SET button The display will read Thermostat Set Point High Press the UP or DOWN arrow keys to scroll through the parameters or press the ALARM CANCEL button to exit VII INTELA TRAUL continued 18...

Page 20: ...antity of warm food has recently been added or the door was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature c INTELA TRAUL setting too high readjust per instructions on page 11 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for the cab...

Page 21: ... of said control which proves to be defective Inspection by the TRAULSEN Service Department of parts claimed defective shall be final in determining warranty status The warranty is to include repair or exchange of any defective In Warranty control or part s of said control for Part s Any TRAULSEN INTELA TRAUL supplied part s found to be defective Labor The labor charges from a TRAULSEN Certified S...

Page 22: ...uver assembly for all UL models Shelf Pin 344 24759 00 Replacement shelf pin Side Panel Exterior Stainless steel exterior side panel X OTHER X a SERVICE INFORMATION Before calling for service please check the following Is the electrical cord plugged in Is the fuse OK or circuit breaker on Is the power switch ON If after checking the above items and the unit is still not operating properly please c...

Page 23: ...age 6 E F G Gaskets 5 H Hinge 4 5 I Internal Time Clock 6 INTELA TRAUL 3 4 5 6 17 J K L Legs 2 Louver Assembly 4 5 M Manual Defrost Cycle 14 N O P Power Supply 3 R Return Authorization 2 Room Temperature Offset 16 S Serial Tag 1 Shelf Pins 2 Shelves 2 5 Smart Recovery 6 T Thermostat Set Point High 10 Thermostat Set Point Low 11 U V Vinyl Protective Covering 2 W Warranty 19 Warranty Registration 21...

Page 24: ...Traulsen Co Inc 4401 Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration ...