Page 16
Troubleshooting Steps
Printed 3/18/98
Travis Industries Pellet Stove Troubleshooting Guide (
1994)
S
TOVE
N
OT UP TO
T
EMPERATURE
The convection blower turns on when the heater reaches sufficient temperature (120
°
F. on the exhaust box).
This takes 10 to 30 minutes depending upon the burn rate. Poor pellets or especially dirty systems will
decrease the heating potential of the stove, leading to longer warm-up times.
Remedy
Allow the heater to warm sufficiently.
C
ONVECTION
B
LOWER
F
AULTY
The convection blower pushes air through the heat exchanger tubes located along the top of the firebox,
transferring heat from the firebox to the room. It also performs a necessary cooling function for the internal
components. To check the convection blower, follow the steps below.
Clean off this screen
(included on certain models)
Electrical Leads
Convection
Blower Motor
Keep your fingers away from the impellers and connect the two electrical leads from the convection blower to
a hotwire and plug it into an electrical outlet. If the blower does not turn on, it will need to be replaced. To
gauge whether the convection blower pushes enough air, compare it to a brand new convection blower for a
side by side comparison. If the velocity of air is considerably less or the noice considerable more, replace
the blower.
1
2
Make sure the wires to the convection blower (two black wires) are not damaged or disconnected. Remove the
convection blower.
Convection
Blower
Use a 7/16" wrench or socket
driver to remove this nut
(some models use a bolt)
Disconnect the
two plugs from
the control box
Clamp
Wires leading to convection
blower (two black wires)
Hotwire
The blower may shut off only when the stove is at its hottest temperatures. Replace the convection blower
and start the stove. With the convection blower on low, let the stove reach maximum temperature. If the
blower shuts off, it indicates that the thermal protection on the blower is too sensitive. Replace the blower.
3
Remedy
Fix or replace any wiring. If the convection blower does not work when hotwired, or if it pushes little air,
replace. If it does not work when the heater is at full temperature, replace.
Summary of Contents for 400 PI