Page 28
Removal Instructions (
Unplug the Heater First!
)
Printed 3/18/98
Travis Industries Pellet Stove Troubleshooting Guide (
1994)
A
UGER
T
UBE
Rarely does the auger tube require removal or replacement. Only in cases in which the auger flight can not be
removed from the auger tube should the auger tube be removed and replaced. The auger tube is attached to the
hopper and sealed in place with silicone.
1. Remove the hopper.
2. Access the inside of the hopper (on inserts the hopper cover plate will need to be removed). Remove the
screws that attach the auger tube to the hopper.
3. Peel the auger tube away from the hopper. Silicone is used to seal the auger tube to the hopper. When
replacing the auger tube, apply high-temperature silicon to the perimeter to insure a good seal.
A
UGER
F
LIGHT
Rarely does the auger flight require removal. Jammed augers can usually be freed by inserting a piece of wire
up the feed tube to dislodge stuck pellets (see "Auger is Jammed"). Augers that are extremely jammed may
not be freed by this method. In these cases, remove the auger motor and manually turn the auger flight (use an
allen wrench inserted into the lock screw or a pipe wrench on the drive collar). If this does not work, remove
the hopper and try to dislodge pellets with the hopper upside down. If this does not work, remove the auger
flight, following the directions below.
1. Remove the hopper from the heater.
2. Remove the auger motor.
3. Place the hopper upside down against a work surface.
4. Remove the four bolts that hold the motor stop and auger bearing holder in place.
Motor Stop
These two bolts
hold the auger
bearing holder
Bearing Holder
These two bolts
hold the motor stop
7
/16
" Wrench
Note the
silicone sealing
the auger to the
hopper.
Tap here with a
hammer to
dislodge the
auger flight.
Drive Collar
This area must be
sealed with silicone.
5. Grasp the auger shaft and pull it from the auger tube. If it does not come free, use a hammer and punch to
gently tap the auger shaft out of the auger tube from the opposite end.
NOTE
: A pipe wrench may be
used on the drive collar to turn the auger and aid in removal.
Summary of Contents for 400 PI