Troubleshooting Steps
Page 5
Printed 3/18/98
Travis Industries Pellet Stove Troubleshooting Guide (
1994)
C
ONTROL
B
OX
F
AULTY
The control box acts as the "brain" of the stove, timing the intervals of the auger, monitoring the start-up
features of the stove, and housing the wiring configuration. Many different problems may be encountered
with a faulty control box.
The best way to check the control box is to switch
out the control box. Hook up a new control box and
check to see if this fixes the problem. If it does,
use the new control box.
O L D
N E W
Remove both of the
molex connectors
that attach here.
Use a 5/16" nutdriver to remove the two
screws that hold the control box in place.
Remedy
If the stove works after replacing the control box, the control box was faulty (check internal fuse).
S
WITCH
B
OX
F
AULTY
The switch box houses the user controls of the stove. Almost all of the electrical circuits run through the
switch box, making its operation crucial to nearly every aspect of the heater's operation.
On stoves the switch
box is removed by
removing two screws
with a 5/16" nutdriver.
On inserts the switch
box clips into place on
the left side.
The best way to
check the switch
box is to switch out
the switch box.
Hook up a new
switch box and
check to see if this
fixes the problem. If
it does, use the new
switch box.
O L D
N E W
Attach this molex connector
to the top connector on the
control box.
Remedy
If the stove works after replacing the switch box, the switch box (or wiring) had a faulty component inside.
W
RONG
M
ODEL OF
C
ONTROL
B
OX
New control boxes were introduced in 1993 to accommodate the igniter. When a 1993 or later control box is
placed in an older stove it will turn off 15 minutes after starting. When a 1992 or earlier control box is placed
in a 1993 or later stove it will not feed pellets or turn on, but the indicator light will come on.
Remedy
Go to Appendix 3 for details on which type of control box should be used and how to retrofit.