Installation
(for qualified installers only)
51
© Travis Industries
4100728
100-01254_000
10 Replace the remaining firebox components. NOTE: Make sure the log is pushed all the way to the
back of the firebox. This prevents sooting under the log..
11 Replace the glass.
12
Remove and discard the screws (see “a” below) holding the stock regulator in place (see “b” below).
Remove the stock regulator and gasket (see “c” below). Place the LP regulator in place, making
sure the pre-fitted gasket (see”c” below) is in place. NOTE: There is a label on the base of the
regulator knob indicating regulator type (NG or LP). Secure the regulator with the screws included
with the regulator – tighten to 25 lb-in of torque (2.82 NM). Place the included label on the valve body
where it can be easily seen to insure proper identification.
NOTE: Leak test this area after the
heater is installed, gas is connected, and the main burner is lit.
a
T-20 Torx or
Slotted Screwdriver
b
c
d
13
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve.