Sturbridge Blower
(Part # 99000154)
Page 1 of 4
12/4/02
Travis Industries, Inc.
Compatibility
• Lopi Sturbridge Cast Gas Stove
Packing List:
• Blower • Blower Cover • Wiring Harness • Snap Disk • Power Cord • Strain Relief
• (4) Nuts & (4) Washers • (4) Grommets with Spacers • Rheostat Control Rod • 1/16” Hex Wrench
• Rheostat Knob • Remote Receiver Heat Shield (used only if using a remote)
Important Warnings
5
Turn the gas control valve to off and make sure the appliance has fully cooled prior to conducting service.
6
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Installation
1
Slide the thermodisk into the holder underneath the firebox.
Snap Disk Bracket
(attached to stove)
Snap Disk