E. Child-Proof Function : 

see

Figure 7

1  There is a CHILD-PROOF switch at the back of the Remote Transmitter.
2  Slide the CHILD-PROOF switch to position marked C/P to activate the CHILD-PROOF function and the 

child-proof function icon will appear on the LCD.

3  In CHILD-PROOF the Remote Transmitter will not operate the Remote Receiver until the "child-proof" 

code is used or the switch is returned to the other position.

4  Press the Up and Down buttons in the following sequence: 

Up-Down-Down-Up-Down

, within 2seconds, 

button function will be temporarily restored, the child-proof function icon will disappear from the LCD.

5  If no button is pressed within 2 minutes, the Remote Transmitter will return to the Child-Proof function and 

the child-proof function icon will reappear on the LCD until the Child-Proof switch is slide back to the 
other position.

Set temperature

Adjust temperature

Control

1. Press the "TIMER" button the "---" 

will start to flash.

2. Use the "UP" and "DOWN" buttons 

to set the Time.

3. Press Manual or Auto On/Off 

buttons to start the timer.

D.   Timer Mode: 

see

Figure 6

1  You can set the timer to the length of time you want the GAS Fireplace, AGP Pellet Stove or GAS Insert to 

operate (1 to 120 minutes).

2  Press the "TIMER" button once. The Timer display "----" will blink.
3  Press the Up and Down buttons to set the timer. The LCD will display the time chosen.
4  The timer setting can be cancelled at any time by press and hold the "TIMER" button.
5  Press Manual or Auto On/Off button to turn on the GAS Fireplace, AGP Pellet Stove or GAS Insert.
6  The GAS Fireplace, AGP Pellet Stove or GAS Insert will turn off at the end of the timer setting.

C. Auto Mode: 

see

Figure 5

1  Set the desired target temperature.
2  Press the Auto On/Off button once to activate the Auto mode.  In Auto Mode the Remote Transmitter will 

automatically turn on the GAS Fireplace, AGP Pellet Stove or GAS Insert when the room temperature is 
below the target temperature and turn off the GAS Fireplace, AGP Pellet Stove or GAS Insert when the 
room temperature is above the target temperature.

3  Press Auto On/Off button or Manual On/Off buttons to turn off the GAS Fireplace, AGP Pellet Stove or 

GAS Insert (if it is already on) and exit Auto Mode.

WARNING: IT TAKES SOME TIME FOR THE 

RECEIVER TO RESPOND TO THE TRANSMITTER.DO NOT PRESS THE MANUALOR AUTO 
ON/OFF BUTTONS MORE THAN ONCE WITHIN 2 SECONDS FOR CORRECT OPERATION.

Figure 5

Figure 6

Summary of Contents for 99300687

Page 1: ...may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or...

Page 2: ...ram the receiver to the remote as per the instructions 7 Replace access panels and side covers 3 Connect wires from the thermostat receiver to the wires labeled TSTAT from the main wire harness on the left side of the unit orientation does not matter 4 Attach the thermostat receiver to the thermostat bracket with 4 screws 5 Replace the receiver and bracket into the cutout on the side of the unit t...

Page 3: ...to the Remote Receiver See Figure 3 Figure 2 Installation of the Receiver to a Junction Box FIREPLACE REMOTE PRESS TO OPEN OFF ON REMOTE BAT LOW 1 2 Installing the Receiver for Gas Fireplace or Insert Wall Mount 1 Make sure the slide switch on the Remote Receiver is at the OFF position 2 Gas Appliance Receiver Wire Installation See Figure 1 We recommend the receiver wires to be installed in a para...

Page 4: ... into the Remote WALL MOUNT and then release The battery compartment will pop out of the Remote WALL MOUNT 3 Slide open the battery door and replace batteries 4 Replace the battery door and slide the battery compartment back into the Remote WALL MOUNT 5 After you take out the batteries wait for at least 1 minute before putting fresh batteries into the Remote WALL MOUNT and Receiver 6 Use fresh alk...

Page 5: ...re Manual Auto and Timer Use the Up and Down buttons to set the target temperature between 45 o F and 90 o F or 8 o C and 32 o C WARNING THE REMOTE WALL MOUNT WILL AUTOMATICALLY SWITCH OFF THE GAS Fireplace AGP Pellet Stove or GAS Insert WHEN THE BATTERIES IN THE REMOTE WALL MOUNT IS LOW B Manual Mode see Figure 4 1 Press the Manual On Off button once to light the GAS Fireplace AGP Pellet Stove or...

Page 6: ...timer to the length of time you want the GAS Fireplace AGP Pellet Stove or GAS Insert to operate 1 to 120 minutes 2 Press the TIMER button once The Timer display will blink 3 Press the Up and Down buttons to set the timer The LCD will display the time chosen 4 The timer setting can be cancelled at any time by press and hold the TIMER button 5 Press Manual or Auto On Off button to turn on the GAS F...

Page 7: ...ure 9 6HR Safety Timer FACTORY DEFAULT IS ON Enable Timer Set to ON In case of Transmitter failure Malfunction Battery run out or out of transmission range The Receiver will shut down the GAS Fireplace AGP Pellet Stove or GAS Insert automatically after 6Hr of no Transmitter signal detection Disable Timer Set to OFF The Receiver GAS Fireplace AGP Pellet Stove or GAS Insert will continue operate in ...

Page 8: ...ition wait for 1 minute and repeat step 3 to 6 8 If you desire to operate multiple Remote Receivers with the one Remote Wall Mount continue to hold the button on the Remote Wall Mount as you bring the Remote Wall Mount within 5 feet of each Remote Receiver then slide the slide switch on the Remote Receivers to the REMOTE position Each will acknowledge receipt of coding with a beep Page 5 of 6 RECE...

Page 9: ...n between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Equipment Requirements This digital apparatus does not exceed the class A Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations...