GS2/MV Basic Wall Mount Remote Installation
with AC Adapter
SKU# 99300696
Page 4 of 18
17602250 - 10/7/22
Travis Industries, Inc.
RADIANT STOVE NOTE:
If a blower is being uesd, install the blower kit first and discard the power cord and strain
relief bracket from this kit. With the blower kit installed follow the steps below to electricly ground the accessories to
the appliance belly pan.
a. Disconnect the blower ground from the strain relief bracket
b. Install the AC adapter ground to the strain relief bracket where you just removed the blower ground.
c. Reinstall
the
blower
ground on the extra ground tab attached to the remote reciever ground quick reliease.
1. Install the new strain-relief bracket (stoves
and inserts).
For stoves, the strain relief bracket can be installed anywhere on the belly pan of the appliance that is out of the
way of other components (see suggestions to the right). Insert the stud on the bracket through an available hole
in the belly pan. Secure the bracket with the included 8-32 nut.
With inserts, the bracket installs on the front of the right wall
of the gas control area below the firebox. Use the included
screw to secure the bracket. Use the included screw to
secure the bracket to one of the two existing holes in the
side of the insert (as shown to the right).