Installation
(For Qualified Installers Only)
17
© Travis Industries
4130924
100-01330_004
Installation Example: Class “A” Chimney Retrofit
* Install vent at clearance specified by the vent manufacturer.
Floor Protection
Outside air may be drawn from
a ventilated crawl space.
2” Min.
Class A Chimney Ceiling Support
Roof Flashing
“L” Vent to Class A Chimney Adapter
Class A Chimney
“L” Vent
Storm Collar
Class A Chimney must
maintain clearances outlined
in the chimney’s installation
instructions (usually 2”).
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
500°
F. R
TV
Silic
one
Floor Protection
6” Minimum
6” Minimum
2”
Minimum
“Tee”
Vent
Clearance*
Vent
Clearance*
between sections,
unless otherwise
specified by the
manufacturer.