6
Safety
Precautions
© Travis Industries
4130924
100-01330_004
Do not throw this manual away.
This manual has important
operating and maintenance
instructions that you will need at a
later time. Always follow the
instructions in this manual.
Disconnect the power before
performing any maintenance.
The exhaust system should be
checked at least twice a year for
any build-up of soot or creosote.
Travis Industries, Inc. grants no
warranty, implied or stated, for
the installation or maintenance of
your appliance, and assumes no
responsibility of any
consequential damage(s).
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Soot and Flyash: Formation and Need for Removal
– The products of combustion will contain
small particle of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or
incorrect operation of the room heater will lead to some soot formation which will collect in
the exhaust venting system. The exhaust venting system should be inspected at least once
every year to determine if cleaning is necessary.
NEVER USE SUBSTITUTE MATERIALS FOR ANY PURPOSE ON THIS APPLIANCE.
Establish a routine for fuel, wood burner and firing technique. Check for creosote build-up
daily until you know how often to clean the appliance for safe operation. Be aware that the
hotter the fire, the less creosote is deposited, and weekly cleaning may be necessary in mild
weather even though monthly cleaning may be enough in the coldest months. Contact your
municipal or provincial fire authority for information on how to handle a chimney fire. Have a
clearly understood plan in place for how to handle a chimney fire.
Do not burn this stove if unburned pellets are in the ashpan. These should be removed as they
may ignite.
This
Manual