10
Installation
(For Qualified Installers Only)
© Travis Industries
4012412
100-01270_000
Clearances
Straight Installations
Corner Installations
*
Install the vent at the clearance specified by the vent manufacturer.
NOTE
:
If an interior vertical vent is used, the stove to backwall dimension is determined by the
vent being used. This dimension will vary depending on the brand of pellet vent used. To
determine the distance from the backwall to the stove, connect the "Tee" and add the vent
clearance.
** The floor protection must extend 2” (51mm) beyond the pipe – all vent clearances must be met.
6” Minimum
6” Minimum
2”
Minimum**
“Tee”
3” Minimum
6” Minimum
Through the Wall Installations
Interior Vertical Vents
Floor Protection
6” Minimum
Vent
Clearance*
Through the Wall Vents
6” Minimum
3” Minimum
45° Elbow
45°
Interior Vertical Vents
3” Minimum
6” Minimum
2”
Minimum*
3”
Minimum
“Tee”
Vent
Clearance*
3” Minimum