Installation (for qualified installers only)
19
© Travis Industries
4091008
100-01236_000
1-Piece Surround Panel
DVL – 34” by 44”
96100319
DVL – 30-1/2” by 42”
96100323
NOTE: The panels may be cut down in size and placed within the fireplace opening.
Routing the Power Cord
Because this panel fits flush against the fireplace facing, the panel does not have a notch allowing the power
cord to exit the fireplace. We recommend using the insert wiring kit (sku 97200315) to route power to the
insert. Otherwise, route the power cord behind the panel to the right side (the panel or fireplace may be
notched, if required).
Installation
1. Attach the mounting brackets as shown below.
a. Remove the two screws from the air
deflector.
b. Slide the upper mounting brackets into
place. NOTE: The brackets slide under
the air deflector. Secure the upper
brackets with the included screws.
c. Attach the lower mounting brackets with
two screws (use the lower holes).
d. Replace the two screws removed in step
“a”.
e. Install two screws into the upper holes on
the mounting brackets.
NOTE: The upper screws keep the
brackets from swiveling.