8
Installation
(for qualified installers only)
Travis Industries
4 0 1 1 0 2 5
9 3 5 0 8 1 0 4
Insert Clearances
•
No combustibles may be within, or swing within, 36" of the front of the insert (drapes, doors)
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
Min. 6”
Side
Wall
Combustible or Non-Combustible Mantel
See Table Below
Min. 6”
Combustible Top Facing
Min. 8-1/2”
Side Facing
Min. 10”
12” Min. (from fireplace opening)
Max. 8”
See Table Below
The non-combustible hearth
must be as wide as the face
and extend to both sides.
Width
35-3/4”
35-3/8”
33-1/2”
36-1/4”
34-3/4”
Face Sizing
Discovery, Rosario
Heritage Bay
Salish Bay
Cambridge
FPX Arched or Rect.
Height
26"
25-5/8"
26-3/8"
25-7/8"
26-1/2"
Mantel Clearances
The mantel must be a minimum 10” above the face and a maximum 8” deep.
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Hearth Requirements
•
The heater must be installed on a non-combustible hearth extending a minimum 12" from the fireplace
opening (local codes may require a larger hearth). The hearth must also extend to both sides of the
face (see the table above for the exact width of the face).