Page 13
FREESTANDING INSTALLATION - SPECIFICATIONS
REQUIRED FLOOR PROTECTION:
FRONT: 16"
SIDE:
6"
BACK:
6"
}
}
6 "
From
Faceplate
6 "
16"
CLEARANCE TO COMBUSTIBLES:
Backwall
Sidewall
A
B
E
D
Cornerwall
C
F
Cornerwall
F
C
Single Wall Connector
A. Sidewall to unit ............................
B. Backwall to unit............................
C. Cornerwall to unit ........................
D. Connector to sidewall.................
E. Connector to backwall................
F. Connector to cornerwall .............
Reduced Clearance *
A. Sidewall to unit ............................
B. Backwall to unit............................
C. Cornerwall to unit ........................
D. Connector to sidewall.................
E. Connector to backwall................
F. Connector to cornerwall .............
*
Components required for alcove,
mobile home, and reduced clearance
installations are one of the following
listed double wall connectors and
chimney systems.
¥ DURAVENT model DVL with DURA-PLUS chimney
¥ AMERI-TEC model DCC with model HS chimney
¥ SECURITY model DP with SECURITY model
ASHT or S2100 chimney
¥ METAL-FAB model DW with model TG chimney
¥ Standard Masonry Chimney with any one of the
above listed connectors
Inches
20
18
14
31
20 1/2
25
20
12
10
31
14 1/2
21