Page 33
FIREPLACE INSERT - SPECIFICATIONS (Continued)
FLOOR PROTECTION
:
Hearth of 42" width and 18" depth when the insert is in place (see "E" and "F" below).
CLEARANCE TO COMBUSTIBLES
:
(
NOTE
: Measures for the
bay kit
should be taken before the side bays are put on or to the edge of the
firebox.)
A. Adjacent Sidewall to
Insert
B. Side Facing
C. Top Facing
(Facing with Shield)
D. Mantle to Insert
(Mantle with Shield)
E. Minimum Floor
Protection-Front
F. Minimum Floor
Protection-Side
15"
15"
23"
17"
25"
19"
18"
8"
COMBUSTIBLE SIDEWALL
COMBUSTIBLE MANTLE
A
D
E
F
Fireplace Facing
Combustible Surface
Combustible Surface
Surround Panel
B
C
Edge of
Firebox
LEVELING BOLTS
If your fireplace is stepped down from the hearth, you will be required to use the leveling bolts located
within the hardware package.
Prior to placing the insert
in the fireplace opening,
measure the step-down.
Screw the 1/2" bolts
provided into the threaded
holes in the back corners
of the insert body and
adjust them to match the
step-down measurement.
As you install the insert the
leveling bolts may need
further adjustment. This
may be done by tilting the
insert slightly and turning
the bolts.
BOTTOM VIEW
Leveling
B o l t s