Installation
(for qualified installers only)
13
© Travis Industries
4121120
100-01315
Optional Wall Switch or Thermostat Installation
Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be
installed by a qualified installer.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
Note
:
When using a GreenSmart™ remote, use the receiver for on/off operation (do not use a wall
switch or thermostat).
Warning
:
Make sure all wiring is secure and does not contact hot or moving components.
The wall switch (or thermostat) may bypass the fireplace on/off switch or be installed in
parallel or series configuration (see below).
Parallel Connection
Series Connection
On / Off Switch
ON
On / Off Switch
OFF
On / Off Switch
ON
On / Off Switch
OFF
Thermostat / External
Switch
ON
Heater is
ON
Heater is
ON
Thermostat /
External Switch
ON
Heater is
ON
Heater is
OFF
Thermostat / External
Switch
OFF
Heater is
ON
Heater is
OFF
Thermostat /
External Switch
OFF
Heater is
OFF
Heater is
OFF
To wire the heater in parallel, follow the directions below:
To wire the heater in series, follow the directions below: