F
EATURES AND
S
PECIFICATIONS
P
AGE
5
Installation Options:
¥ Freestanding
¥ Residential or Mobile Home
¥ Horizontal or Vertical Vent
¥ Class A Chimney Retrofit
Features:
¥
Works During Power Outages
(millivolt system)
¥
High Efficiency; Up to 80% for Natural Gas,
82% for LP (Steady State)
¥
Optional Thermostat or Remote Control
¥
Realistic "Wood Fire" Look
¥
Convenient Operating Controls
¥
Variable-Rate Heat Output
¥
Quiet Blower for Effective Heat Distribution
¥
Low Maintenance
Heating Specifications:
Natural Gas
LP (Propane)
Approximate Heating Capacity (in square feet)*
600 - 1600
600 - 1600
High Burn Input Rate (In BTU's)
38,500
36,500
Low Burn Input Rate (In BTU's)
18,700
18,000
Efficiency**
81 %
81.5 %
AFUE (Annual Fuel Utilization Efficiency)
72.4 %
73 %
*
Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.
**
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system.
To measure the net BTU's, multiply the BTU input by the efficiency percentage.
Dimensions
18-3/4"
24"
4-7/8"
Pedestal: 34-7/8"
Brass, Cast Legs: 30-7/8"
Black Legs: 29-1/2"
Measure Clearances
from the Upper Top
Weight: 205 Lbs.
The starter section
is 4-1/8" below the
upper top.
Fuel:
The heater is designed either for natural gas or for propane (but not
for both). Check the sticker on the top of the gas control valve.
Emissions:
This unit has passed the ANSI emission standards for vented room
heaters as tested by OMNI Environmental Services, Inc.
Electrical Specifications:
120 Volts, 1.3 Amps, 60 Hz (150 watts on high)