16
Installation
(qualified installers only)
© Travis Industries, Inc.
5/21/20 - 1534
Tempest Lantern 24v
Polarity
WARNING: Make sure to keep polarity between Lanterns the same.
Do not allow a yellow wire to connect to a white/yellow wire (keep polarity the
same).
IF YOU REVERSE POLARITY, PERMANENT DAMAGE WILL OCCUR.
When wiring multiple Lanterns together using a single 24VAC transformer,
it is important that
the polarity between the
Lanterns are connected in parallel
(all yellow wires connected
together and all white/yellow stripe wires connected together).
Polarity between the Lanterns
and the transformer does not matter.
Yellow
White/Yellow
Yellow
White/Yellow
24V AC
Transformer
Yellow
White/Yellow
Yellow
White/Yellow
24V AC
Transformer
Correct
Incorrect
WRONG!
DO NOT ALLOW A YELLOW WIRE TO
CONNECT TO A WHITE/YELLOW WIRE
CORRECT - ALL YELLOW WIRES TO
CONNECT TO YELLOW WIRES, ALL
WHITE/YELLOW WIRES CONNECT TO
WHITE/YELLOW WIRES.
White
White/Blue
OLDER VERSION
WIRE COLORING