15
Fusion SKI
bathtub
EN
First run
STAGE 1 (see the diagram on page
13)
- Closure of the EV2, EV3 and EV5 solenoid valves.
- Motors and thermoregulator turned off.
- Enabling of the electronic tap with relative temperature
set and of the EV4 fill solenoid valve. The condition
remains until manual stop or until the water level in the
bathtub as verified by the SL1 sensor is reached.
A 60-minute safety timer is provided, after which the
function is interrupted, reporting an anomaly to the
plumbing system (the water fill key flashes red).
STAGE 2 (see the diagram on page
13)
- Closure of the EV2, EV3 and EV5 solenoid valves.
- Motors and thermoregulator turned off.
- Enabling of the electronic tap with relative temperature
set and of the EV4 fill solenoid valve. The condition
remains until manual stop or until the maximum level of
the storage tank as verified by the SL3 sensor is reached.
A 60-minute safety timer is provided, after which the
function is interrupted, reporting an anomaly to the
plumbing system (the water fill key flashes red).
More information
MAINTAINING THE WATER LEVEL IN THE
BATHTUB
When the bathtub is completely filled a maximum
sensor (SL2) and a minimum sensor (SL1) continuously
monitor the water level inside the compensation tank.
SL1 (minimum sensor) = 0, the sensor does NOT detect
water
SL1 (minimum sensor) = 1, the sensor detects water
SL2 (maximum sensor) = 0, the sensor does NOT detect
water
SL2 (maximum sensor) = 1, the sensor detects water
If the lack of water is minimal (e.g., evaporation or a
person gets out):
• The minimum sensor still detects water (SL1 = 1).
• The maximum sensor does not detect water (SL2 = 0).
•
activates automatic filling until conditions are
restored and for a maximum of 60 minutes.
If the lack of water is considerable (e.g., two or more
people get out of the bathtub):
• Both the minimum and maximum sensors do not
detect water (SL1 = 0, SL2 = 0).
•
The recirculation pump moves the water from
the compensation tank to the bathtub.
• The minimum sensor detects water (SL1 = 1, SL2 = 0).
•
activates automatic filling until conditions are
restored and for a maximum of 60 minutes.
1
FILLING THE BATHTUB
Perform a preliminary cleaning of the bathtub using a bit
of water and a mild detergent.
Do not use cloths or cleaners that are abrasive, aggressive
or that contain solvents because they could irreparably
damage the surface of the bathtub.
Do not start any operation until the bathtub has
been completely filled, otherwise the bathtub
could be damaged.
Before filling, once again check the quality of the water
supply. This is very important for the well-being of the
users and for the long life of the bathtub.
For more information see chapter “Characteristics
of the water supply” on page 10.
AUTOMATIC FILLING USING THE KEYPAD
Filling is carried out by following the figures on the side
(follow the instructions for your keypad).
Filling takes place from the bottom of the bathtub, and
once it has finished the tank is filled.
Once the correct level has been reached, the system
automatically stops filling.
At this stage and until filling is completed, no other
functions of the bathtub - except chromatherapy - will
be available.
The automatic bathtub filling cycle is divided into two
distinct stages:
Automatic filling using the keypad
switch on the bathtub with the
ON/OFF key and then press the "fill" key. This activates the automatic
filling of the bathtub, controlled by two level sensors and is confirmed
by the fixed solid blue colour of the key.
ON/OFF