background image

18

Fusion SKI

 

bathtub

 

EN

First run

HOW TO ACTIVATE FUNCTIONS

 DISINFECTION

The disinfection function is an automatic cleaning 

procedure for the bathtub's entire water circuit, including 

the tanks. It should be carried out after every use of the 

bathtub or after long periods of disuse.

HOW TO START IT

Press the "

disinfection

" key.

To prevent accidental use, after the first press the key 

flashes blue. At this point:

A) If it is not pressed again, the key returns to fixed blue 

and nothing happens (the system interprets the first 

press as an accident).

B) If by the third blue flash the "

disinfection

" key is pressed 

again, the function starts and the key turns solid red.

Subsequently: 

-  It is 

filled

 with water until the tank is completely filled 

(SL3 sensor).

-  The two pumps (whirlpool and recirculation) and the 

solenoid valve of the 

disinfectant

 are activated for 30 

seconds. The two pumps remain active for an additional 

five minutes.

After five minutes the bathtub is automatically 

drained

.

It is important to leave the bathtub switched on for at least 

one hour after the end of the disinfection procedure to al-

low for the complete emptying of the pipes.

If the whirlpool is started but the water level in the minipool 

is too low or there is no disinfectant in the reservoir, the key 

will flash red three times and the cleaning will not start.  

In this case fill the bathtub or top up the reservoir using the 

appropriate products.

EMPTYING

Pressing the "

empty

" key activates the bathtub's automatic 

emptying cycle. 

To prevent accidental use, after the first press the "

empty

key flashes blue. At this point:

A) If it is not pressed again, the key returns to fixed blue 

and nothing happens (the system interprets the first 

press as an accident).

B) If by the third blue flash the key is pressed again, the 

emptying cycle starts and the key changes from blue to:

 - 

Flashing red in the first phase of the cycle (it cannot be 

interrupted).

 - 

fixed red in the second phase of the cycle (in this 

moment it is possible to stop the emptying by pressing 

the key again). 

Throughout the entire emptying cycle, both chromatherapy 

and the shower head can be activated. 

It is important to leave the bathtub switched on for at least 

one hour after the end of the disinfection procedure to al-

low for the complete emptying of the pipes.

x2

x2

DISINFECTANT

Summary of Contents for Fusion SKI Series

Page 1: ...Fusion SKI bathtub Installation manual...

Page 2: ...been paid to guarantee the accuracy of this manual The Manufacturer reserves the right to modify the equipment or the documentation at any time without notice Therefore there might be small differenc...

Page 3: ...__________________________________________________8 2 QUALIFICATIONS OF THE INSTALLER ___________________________________________________________8 3 CONNECTIONS REQUIRED_______________________________...

Page 4: ...r modifications that do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the bathtub do not pl...

Page 5: ...ge grating around the perimeter has been installed to help preserve the equipment and the structure If possible non slip flooring has been installed in the area around the bathtub For a recessed insta...

Page 6: ...ive equipment e g gloves safety shoes etc and taking all the necessary safety precautions for those involved and to not damage the bathtub During transport lift the bathtub by holding it exclu sively...

Page 7: ...to a maximum of 1 cm For a recessed installation lower the bathtub into the prepared space If it was not possible to provide a technical inspection port on all sides of the bathtub a pneumatic lift is...

Page 8: ...2 QUALIFICATIONS OF THE INSTALLER Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental cond...

Page 9: ...2 electrical connection power supply The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF BATHTUB INSTALLA TION IN IN IN IN 40 40 Electrical connect...

Page 10: ...ined by the total content of calcium and magnesium present in the water coming from their soluble salts Water classification up to 7 f Very soft water From 7 f to 14 f Soft water From 14 f to 22 f Sli...

Page 11: ...tion to the bathtub using the 1 2 inch female hoses provided Connect the drain of the floor bathtub The plumber is responsible for the choice and type of materials to be used and the verification of c...

Page 12: ...and sheltered from the weather Controlled by a multi pole switch with a contact gap of at least 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Cont...

Page 13: ...olenoid valve For convenience designed as one in the final system there will be two solenoid valves in parallel to increase water drainage speed EV4 bathtub fill solenoid valve EV5 shower head solenoi...

Page 14: ...he feet up to a maximum of 1 cm The water connections have been made properly in accordance with local and national codes and that they can guarantee a perfect seal verification to be carried out afte...

Page 15: ...omatic filling until conditions are restored and for a maximum of 60 minutes If the lack of water is considerable e g two or more people get out of the bathtub Both the minimum and maximum sensors do...

Page 16: ...tive functions except for the drain FILLING Pressing the Fill key starts the automatic filling of the bathtub When pressed the backlight changes from blue to red until the bathtub reaches a sufficien...

Page 17: ...running the key is red If the whirlpool is started but the water level in the minipool is too low the key will flash red three times and the whirlpool will not start TURNING ON LIGHTS Pressing the Lig...

Page 18: ...er the end of the disinfection procedure to al low for the complete emptying of the pipes If the whirlpool is started but the water level in the minipool is too low or there is no disinfectant in the...

Page 19: ...19 Fusion SKI bathtub EN Mount the laminate resin panels as shown in the figure below Decorative panels 1 2 1 1 3 INDOOR INSTALLATION...

Page 20: ...sion SKI installation Edition 12 2017 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres i...

Reviews: