21
Pre-Installation
Fusion
minipool
EN
PARAMETER
OPTIMAL VALUES
between...
VALUES ABOVE OR BELOW CAN...
POTABILITY
Refer to the specific regulations
of the country of use
...cause problems related to the safety and well-being of
users
SUPPLY
PRESSURE
maximum: 300,000 PA (3 bar)
minimum: 150,000 PA (1.5 bar)
HARDNESS
(TH)
between 10°F and 25°F
(100 mg/l-250 mg/l)
...cause build-up that over time can cause damage to the
walls of the minipool, the pipes, the filter system, as well
as the heating unit and pumps. The limescale deposits
can also hide bacterial loads that are not easily reached by
disinfectant products. Installation mandatory.
It is mandatory to install a water softener, choosing the
model according to the hardness of the water.
pH
for bromine treatments it is
recommended to keep the pH in
the range 7.4 to 7.8
...irritation of the eyes and skin of people in the water,
water with little sanitising power, excessive consumption
of chemicals, decrease in the duration of the minipool
components.
ALKALINITY
(TAC)
80 and 125 mg/l (8-12.5°F)
...more likely uncontrollable changes in pH
CHARACTERISTICS OF THE WATER SUPPLY