background image

24

Pre-Installation

Fusion

 

minipool

 

EN

N

L

N

L1 L2 L3

220V~

380V~

ELECTRICAL 

DIAGRAM

Summary of Contents for Fusion Spa 200

Page 1: ...Fusion Spa minipool Pre installation manual EN...

Page 2: ...you to read this manual carefully and to carefully follow all the information contained herein The Treesse team is always available for any information or request for assistance that may be required d...

Page 3: ...___________________________________________________11 4 PREPARATION OF THE INSTALLATION SITE_____________________ 12 FREESTANDING INSTALLATIONS_________________________________________________________...

Page 4: ...2 6 bar operating temperature 5 C min 45 C max Size in cm dimensional tolerances 5mm The manufacturer reserves the right to make improvements to the equipment at any time without prior notice Partial...

Page 5: ...g pressure 2 6 bar operating temperature 5 C min 45 C max Size in cm dimensional tolerances 5mm The manufacturer reserves the right to make improvements to the equipment at any time without prior noti...

Page 6: ...5 C min 45 C max Size in cm dimensional tolerances 5mm The manufacturer reserves the right to make improvements to the equipment at any time without prior notice Partial reproduction without the manuf...

Page 7: ...sand operating pressure 2 6 bar operating temperature 5 C min 45 C max Size in cm dimensional tolerances 5mm The manufacturer reserves the right to make improvements to the equipment at any time with...

Page 8: ...mits are required An incorrect pre installation could cause structural damage to the minipool and void the warranty TEMPORARY POSITIONING The installation of the minipool should be done immediately up...

Page 9: ...WHAT PREPARATIONS ARE REQUIRED To be installed the minipool requires 1 Identification of the installation site 2 Preparation of the installation site 3 Preparation of the plumbing 4 Preparation of the...

Page 10: ...e electrical connections Drain Water supply Technical inspection port IN incoming hot domestic water OUT outgoing cold water 230V C S P in out PR TC EV BS P2 BL 1 BL2 HTR Cromo 230V EVc EVs EVclv 230V...

Page 11: ...nny area with increased exposure during the morning ensures greater well being for users Consider the geological composition of the soil on which the supporting platform will be built Soils that are v...

Page 12: ...nder the bathtub to level it only the feet of the bathtub can be adjusted Remember to ground the structural reinforcement in accordance with electrical codes Prepare A Drainage grating around the peri...

Page 13: ...s will make future maintenance or repairs easier B Drainage grating around the perimeter and in the recess to help preserve the equipment and the structure even for indoor installations C A non slip f...

Page 14: ...ensure proper ventilation of the technical compartment C Non slip flooring CONCRETE SLAB h 10 cm minimum FUSION SPA 200 56 10 measurements in cm See the plumbing and electrical preparations on page 15...

Page 15: ...o the minipool If water service is not available install filters filtration of no less than 50 microns upstream of the plumbing system that guarantee characteristics comparable to those of tap water T...

Page 16: ...ction from 10 to 36 C 1 2 M B Floor drain flush with the floor 40 C Electrical connection power cord type H05 with three wires single phase 230V 110 10 10 90 40 A C B FUSION SPA 220 A Water connection...

Page 17: ...95 20 20 30 A 40 B 80 20 20 30 40 A C C B 40 A C B FUSION SPA 200 FUSION SPA 231 FUSION SPA 230 A Water connection from 10 to 36 C 1 2 M B Floor drain flush with the floor 40 C Electrical connection p...

Page 18: ...90 12 12 40 A C B FUSION SPA 220 FUSION SPA 230 A Water connection from 10 to 36 C 1 2 M B Floor drain flush with the floor 40 C Electrical connection power cord type H05 with three wires single phase...

Page 19: ...1 2 M B Floor drain flush with the floor 40 C Electrical connection power cord type H05 with three wires single phase 230V In the figures installation to the left Installation to the right mirrors th...

Page 20: ...to 22 f Slightly hard water From 22 f to 32 f Fairly hard water From 32 f to 54 f Hard water more than 54 f Very hard water 1 f 10 mg calcium carbonate per litre of water WATER ALKALINITY Alkalinity C...

Page 21: ...m as well as the heating unit and pumps The limescale deposits can also hide bacterial loads that are not easily reached by disinfectant products Installation mandatory It is mandatory to install a wa...

Page 22: ...male hose provided If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the d...

Page 23: ...equal to 60A or in any case adequate for the absorption of the bathtub 6 ELECTRICAL PREPARATIONS Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be...

Page 24: ...24 Pre Installation Fusion minipool EN N L N L1 L2 L3 220V 380V ELECTRICAL DIAGRAM...

Page 25: ......

Page 26: ...Notes Notes...

Page 27: ...e small differences between this manual and the product you have received we apologise in advance for any inconvenience The total or partial reproduction of this manual without the Manufacturer s cons...

Page 28: ...on Spa pre installation Edition 10 2017 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres...