background image

17

Fusion Spa

 

minipool

EN

First run

the power and restore it after about 30 seconds using 

the product's main power switch and check the reason 

for this anomaly (leaky pipes, obstructed supply valves, 

insufficient pressure). 

During the use of the minipool the system automatically 

maintains  the  water  level  flush  with  the  edge  of  the 

bathtub.

More information

MAINTAINING THE WATER LEVEL IN THE 

MINIPOOL 

When  the  minipool  is  completely  filled  a  maximum 

sensor (SL2) and a minimum sensor (SL1) continuously 

monitor the water level inside the compensation tank. 
SL1 (minimum sensor) = 0, the sensor does NOT detect 

water

SL1 (minimum sensor) = 1, the sensor detects water

SL2 (maximum sensor) = 0, the sensor does NOT detect 

water

SL2 (maximum sensor) = 1, the sensor detects water

If the lack of water is minimal (e.g., evaporation or a 

person gets out):

•  The minimum sensor still detects water (SL1 = 1).

•  The maximum sensor does not detect water (SL2 = 0).

• 

 activates automatic filling until conditions are 

restored and for a maximum of 60 minutes.

If the lack of water is considerable (e.g., two or more 

people get out of the minipool):

•  Both the minimum and maximum sensors do not 

detect water (SL1 = 0, SL2 = 0).

• 

 The recirculation pump moves the water from 

the compensation tank to the minipool. 

•  The minimum sensor detects water (SL1 = 1, SL2 = 0).

• 

 activates automatic filling until conditions are 

restored and for a maximum of 60 minutes.

1

FILLING THE MINIPOOL

Perform a preliminary cleaning of the minipool using a 

bit of water and a mild detergent. 

Do not use cloths or cleaners that are abrasive, aggressive 

or that contain solvents because they could irreparably 

damage the surface of the minipool.

Do not start any operation until the minipool has 

been completely filled, otherwise the minipool 

could be damaged.

Before filling, once again check the quality of the water 

supply. This is very important for the well-being of the 

users and for the long life of the minipool. 

For more information see chapter “Characteristics 

of the water supply” on page 13.

AUTOMATIC FILLING USING THE KEYPAD

Filling is carried out by following the figures on the side 

(follow the instructions for your keypad).

Filling takes place from the bottom of the bathtub, and 

once it has finished the tank is filled.

After reaching the correct level, the system automatically 

stops  the  filling  and  makes  available  the  functions  of 

whirlpool, recirculation, ozone and heater. 

At  this  stage  and  until  filling  is  completed,  no  other 

functions of the minipool - except chromatherapy - will 

be available. 

During  the  filling  phase,  if  the  times  for  reaching  the 

minimum (90 min) and maximum (60 min) levels in the 

overflow tank are not met, alarms "AL1" (minimum level) 

and "AL2 "(maximum level) will be triggered, stopping 

all operation. In this case, you will have to disconnect 

Automatic filling using the keypad: 

pressing the key activates the 

automatic filling of the minipool, controlled by two level sensors and 

confirmed by the fixed blue key.

Automatic filling using the keypad

simultaneously pressing the 

 and 

 keys activates the 

automatic filling of the minipool, controlled by two level sensors and 

confirmed by the "FILL" LED  

Summary of Contents for Fusion Spa 230

Page 1: ...Fusion Spa minipool Installation manual...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...10 3 CONNECTIONS REQUIRED__________________________________________________________ 11 4 PLUMBING CONNECTIONS_________________________________________________________ 13 CHARACTERISTICS OF THE WATER S...

Page 4: ...odifications that do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not plac...

Page 5: ...de in compliance with current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the bathtub at the end...

Page 6: ...personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those involved and to not damage the minipool During transport lift the minipool by holdi...

Page 7: ...he height of the minipool s feet to compensate up to a maximum of 1 cm For a recessed installation lower the minipool into the prepared space If it was not possible to provide a technical inspection p...

Page 8: ...water C drain More information WHAT IS THE SAND FILTER The sand filter is an effective minipool filter connected to the recirculation pump s feed line It consists of a large container that is two thir...

Page 9: ...3B 3A 3A 2 3 5 4 6 0 5 1mm 7 10 8 10A 10A 11A 10B 11B 11C 11 12 13 0 5 1mm B 9 Caution Do not inhale Carefully clean and verify that the gaskets are still in place INTERIOR top view Caution Make sure...

Page 10: ...it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and authorised by the Man...

Page 11: ...al and plumbing connection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR...

Page 12: ...rical connections Drain Water supply Technical inspection port IN incoming hot domestic water OUT outgoing cold water 230V C S P in out PR TC EV BS P2 BL 1 BL2 HTR Cromo 230V EVc EVs EVclv 230V heater...

Page 13: ...Ideal values of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it pos...

Page 14: ...male hose provided If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the d...

Page 15: ...th a contact gap of at least 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control uni...

Page 16: ...ed and properly connected to the pipes The water connections have been made properly in accordance with local and national codes and that they can guarantee a perfect seal verification to be carried o...

Page 17: ...bit of water and a mild detergent Do not use cloths or cleaners that are abrasive aggressive or that contain solvents because they could irreparably damage the surface of the minipool Do not start an...

Page 18: ...ng sanitising ozone active KEY COMBINATIONS FILL bathtub EMPTY bathtub change mode from ACTIVE to STANDBY key entry exit from sleep mode WHITE sleep mode NOT active BLUE sleep mode active whirlpool ac...

Page 19: ...n to stop the function The first time it is recommended to leave the whirlpool in operation for at least 2 3 minutes to expel the air that may be present in the plumbing system CHROMATHERAPY Chromathe...

Page 20: ...hing the LED flashes the key for about 3 seconds during backwashing the letters FLT appear on the display Backwashing disables The recirculation pump The heater The ozonator A backwash cycle can be in...

Page 21: ...lay even if it is not visible it is still active then press the key emptying in progress is indicated by the flashing blue key The emptying of the minipool can be activated at any time Emptying lasts...

Page 22: ...disconnect the power supply to the bathtub and switch it on again after 30 seconds If the problem persists verify that the connection with the control unit is correct and has not been tampered with Ot...

Page 23: ...LL alternating with the temperature the functions remain enabled the system will start filling the bathtub to restore the level see the section on filling the minipool on page 17 The notification is...

Page 24: ...After the first cleaning of the bottom the problem should no longer exist Cleaning the bottom with a minipool cleaner Make sure you have used sand with granularity from 0 5 to 1 mm suitable for this...

Page 25: ...25 Fusion Spa minipool EN Mount the laminate resin panels as shown in the figure below Decorative panels 1 2 1 1 3 3 INDOOR INSTALLATION OUTDOOR INSTALLATION...

Page 26: ...ty Under these conditions or when not used advise the owner to use a fixed or mobile cover to protect the minipool we recommend the optional Treesse covers In addition to preserving the surfaces the c...

Page 27: ...e small differences between this manual and the product you have received we apologise in advance for any inconvenience The total or partial reproduction of this manual without the Manufacturer s cons...

Page 28: ...sion Spa installation Edition 03 2018 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres i...

Reviews: