DESCRIPTION OF PARTS

ACTIVE Mode

In 

 ACTIVE

 mode, the spa is maintained under such conditions to be readily accessible to the user.

If there are no water level alarms, the recirculation pump is always active to filter the water.
When the control panel is turned on, it will be put in the same state at it was before the shutdown.
You can switch from 

STANDBY

 mode by pressing the two 

UP

 and 

DOWN

 scroll keys scroll 

UP DOWN

.

STANDBY Mode

STANDBY

 mode is used when it is expected that the spa will remain unused for a certain period of time 

and keeps it at a temperature, selectable by the user, below the regular operating temperature of the 
product.
The default value is 25°. In this state, the functions are disabled, and the recirculating pump, if there are 
no water level alarms, is activated to maintain the temperature or to filter the water.
To enter and exit the 

STANDBY

 mode you must press the two 

UP

 and 

DOWN 

scroll keys.

 
The 

STANDBY

 mode is maintained even in the event of an outage and power surge.

When the spa is in 

STANDBY

 state, the display shows the message "

SBY

".

If the heater is running, the 

LED

 is active.

During the 

STANDBY

 mode, press the 

UP

 and 

DOWN

 keys to vary the temperature in 

STANDBY

 

mode.
The minimum temperature can be set at 13 °C.
During the 

STANDB

Y mode, for filtering and sanitizing are activated 2 times a day (every 12 hours) 

both the pump and the ozonator.
During filtering, the

 LED

 is active.

Hydromassage

By pressing the HYDROMASSAGE key you will enable the function in 
the spa.
The function is indicated by the HYDROMASSAGE LED that turns on.
This function can only be activated with the level of water at steady 
operating values.
With EMPTYING active, the hydromassage is deactivated.
If not interrupted from the keyboard, it will turn off automatically after 
20 minutes.

CONTROL PANEL

Summary of Contents for Minipool REST

Page 1: ...treesse Minipool REST OPERATION AND MAINTENANCE MANUAL 03_2015...

Page 2: ...treesse...

Page 3: ...A questa garanzia di qualit e comfort si aggiunge una forte innovazione e un design ricercato Non ci resta che augurarLe un buon relax Gruppo Tre S S p a Dear Customer We thank you for choosing a pro...

Page 4: ...ENTS DIRECTIONS FOR USE GENERAL FUNCTIONS MAINTENANCE CLEANING THE SURFACES WARRANTY WARRANTY CONDITIONS WARRANTY CERTIFICATE COUPONS TO BE SENT 27 28 USING THE TUB FILLING FUNCTION DESCRIPTION OF PAR...

Page 5: ...rer will not be liable for any damage caused by improper use of the product We recommend you check that the product is prepared in accordance with the indications given in the technical data sheet and...

Page 6: ...FILLING EMPTYING treesse Pg 6 treesse GENERAL FUNCTIONS DIRECTIONS FOR USE CONTROL PANEL...

Page 7: ...elle qualit dell idromassaggio senza la presenza fisica in vasca del dispositivo generante l idromassaggio migliorando nettamente il rapporto ergonomico con il prodotto Per il funzionamento del sistem...

Page 8: ...llo stesso Per il funzionamento del sistema vedere la specifica sul pannello di controllo vedi pg 15 e 22 For the operation of the draining system see the specification on the control panel see page 1...

Page 9: ...ION OF PARTS CONTROL PANEL Description of KEYS On Off HYDROMASSAGE key LIGHT COLOUR THERAPY key Scroll Button UP Scroll Button DOWN Manual FILLING keys combination Manual EMPTYING keys combination On...

Page 10: ...eesse Pg 10 DESCRIPTION OF PARTS Description of LEDs FILLING active EMPTYING active HYDROMASSAGE active COLOUR THERAPY LIGHT active CLEANING SANITIZING active HEATING active TEMPERATURE Adjustment CON...

Page 11: ...displays an alarm message A1 minimum level and AL2 maximum level thereby locking all functions In that case you will have to turn off and on again after about 30 seconds the power switch of the produ...

Page 12: ...maintain the temperature or to filter the water To enter and exit the STANDBY mode you must press the two UP and DOWN scroll keys The STANDBY mode is maintained even in the event of an outage and powe...

Page 13: ...By pressing the LIGHT COLOUR THERAPY key again the colour enabled at that time is disabled By pressing it repeatedly you can manually scroll through the colors By pressing the LIGHT COLOUR THERAPY ke...

Page 14: ...d When the ozonator is running the LED is active Alarms Alarm temperature If the temperature of the water in the spa exceeds 42 C all functions are turned off the display shows the message HI alternat...

Page 15: ...Water level alarm Both inACTIVE and STANDBYmode if there is no minimum water level for more than 3 seconds an alarm is activated and the display shows the message LL alternating with the temperature...

Page 16: ...NON USARE PRODOTTI ABRASIVI SOSTANZE A BASE ALCOLICA ACETONE O ALTRI SOLVENTI ASSOLUTAMENTE NON UTILIZZARE SPUGNE CON RETINE METALLICHE O ABRASIVE WATER TREATMENT To keep the water purified it is reco...

Page 17: ...duct manufacturing cannot be held in any way liable for harm damage to people animals TREESSE or property deriving from non compliance with the specifications indicated in the installation and mainten...

Page 18: ...treesse treesse Pg 18 NOTES...

Page 19: ...treesse treesse Pg 19 NOTES...

Page 20: ...Gruppo Tre S s p a 01036 Nepi Vt italia S S Cassia Km 36 400 Zona ind Settevene Tel 39 0761 527242 Fax 39 0761 527223 e mail info gruppotres it www gruppotres it...

Reviews: