33
minipool
Q
uarz
The Treesse minipools are built in compliance with
European laws (EN 60 335-2-60) and are tested during
production to ensure the safety of the installer and user.
The electrical preparations are to be performed by a
suitably qualified and certified electrician.
All electrical preparations must be performed only
after disconnecting the electricity in the work area.
The electrical connection must be:
• Performed in a
fixed and permanent manner
, without
intermediate splices, in accordance with regulations of
the country of installation.
• Sufficient for the current absorbed by the bathtub
(see technical specifications).
• Provided with a functioning
ground as per current
regulations
.
• Protected against splashing water
, then placed
in a dedicated room, closed and sheltered from the
weather.
5
ELECTRICAL PREPARATIONS
• Controlled by a
multi-pole switch
with a contact gap of
at least 3 mm and a breaking capacity equal to 60A (or
in any case adequate for the absorption of the bathtub).
• Controlled by a
differential switch
no larger than
30mA.
The control unit's power supply cable must be of the
H05 type with three wires (single-phase 230V) or five
wires (three-phase - 380V) whose gauges are adequate
for the absorption of the minipool (see "Pre-installation
sheet"). Its size depends on the absorbed current and the
distance of the minipool from the main electrical cabinet.
In addition, if the minipool is installed outdoors, the
power cord from the main electrical panel to the minipool
must pass through an underground duct, adequately
protected against freezing with insulation.
The Manufacturer is not responsible for connec-
tions made in a way that does not comply with
local codes, the specifications in this pre-installa-
tion sheet or tampering with any electrical component of
the minipool.
min.
60 cm
min.
60 cm
min.
60 cm
min.
60 cm
min.
60 cm
MIN. 230 cm
MIN. 230 cm
Local regulations prohibit any electrical installation (plug sockets, switches, lamps, etc.) in the area surround-
ing the minipool for a distance of at least 60 cm and a height of 230 cm.
Pre-Installation
EN